Your oven has been manufactured as 220-240 V 50/60 Hz. AC
power supply compliant and requires a 16 Amp fuse. If your power
network is different that these indicated values, refer to an electrician
or your authorized service.
When you need to replace the electrical fuse, please ensure that
electrical connection is made as follows:
• Phase (to live terminal) brown cable
• Blue cable to neutral terminal
• Yellow-green cable to earth terminal
Oven disconnecting switches must be in an accessible place for final
user while oven is in its place.
Power supply cable (plug in cable) mustn't touch hot parts of the appliance.
If supply cord (plug in cable) is damaged, this cord must be replaced by the
importer or its service agent or an equally competent personnel to
prevent a hazardous situation.
CONTROL PANEL
Digital Panel Visual
Mechanical Panel Visual
Adjustment can be made only when button is popped for models with
pop-up button.
Make sure that button is popped by pressing on
the button as shown in the figure at left side.
Figure 6 *
14