8-59
January 24, 2017
Structure Function Principle
CLG835H
Sound and Light Alarm System/Audible and Visual Alarm System/Acousto-optic alarm system
Circuit for backup alarm
Backup alarm
An intermittent buzzer is applied as the backup
alarm, which works together with the backup light
during the operator's backup operation.
The electrical parameters of backup alarm
1. Rated voltage 24V; 2. working current
0.
3A;
3. sound level 107dB±4dB(A).
The detection procedures of backup alarm
1. Connect the 24V DC power (+) to the termi-
nal at #1 hole site of the backup alarm, while
the (-) to the terminal at #2 hole site;
2. Turn on the DC power;
3. Back up alarm makes alarm sound and the
sound level is in the range of 107dB±4dB(A).