8-40
Structure Function Principle
January 24, 2017
Monitoring system
CLG835H
Circuit for air filter blockage alarm
The intake air filter alert indicator is lit if the intake resistance exceeds 6.3KPa. The type of air filter block-
age alarm switch is normally open.
Circuit for alternator charging indication
It is used for monitoring whether the alternator supplies power to the external circuit after the machine
starts. The indicator goes out, which means the engine is in the state of supplying power outward.
P18E00052
P18E00053