background image

MODEL

4-MD
5-MD

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

   INTRODUCTION

This instruction sheet provides you with the information required 
to safely own and operate your product. Retain these instructions 
for future reference.
The product you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. This product has been carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your item(s) carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 
YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

SAFETY GUIDELINES

WARNING:

 To reduce the risk of electrical shock, remove the pump 

from power before attempting to service or remove any part.
Read all instructions and safety guide lines thoroughly. Failure to 
follow the guidelines and instructions could result in serious bodily 
in jury and/or property damage.
Do not pump flammable liquids such as gasoline or fuel oil.
Make sure pump is grounded.
During operation, the area surrounding the pump may be covered 
with water; take care when handling the pump. 
Do not disconnect plumbing connections when pump is in operation.
Do not stand in water when changing fuses.

PUMP CONSTRUCTION

The patented magnetic drive pump design consists of a cylindrical 
drive magnet attached to the motor shaft, which rotates around a 
chemical-resistant plastic separator housing. Inside this housing is a 

magnet fixed to the impeller. The impeller assembly is free to rotate 
on a spindle that is supported at both ends. The spindle is held 
captive and does not turn. Front and rear thrust washers are utilized 
as wear bearings. The washers are held captive and do not revolve. 
This prevents wear on the shaft. With the magnetic coupling the 
motor drives the impeller. This coupling eliminates the conventional 
shaft seal and its possibility of leakage.

PUMP MATERIALS

The pump's plastic parts are made of glass-filled polypropylene. 
The spindle shaft and thrust washers are titanium. The impeller-
driven magnet is uncoated Ceramagnet A (barium ferrite) type 
ceramic, and the static O-ring seal is Buna-N.

INSTALLATION

This pump is assembled and tested at the factory, and is ready 
for immediate use. It may be installed in any position, including 
vertically with the pump head down. To ensure proper plumbing 
connections, see the SPECIFICATIONS table to determine the 
intake and discharge sizes of your pump. Use thread sealer on 
all pipe connections and hand-tighten only. Tighten all wing nuts 
before operating the pump. The motor nameplate lists all electrical 
data. Make sure the pump is connected to proper voltage before 
operating. When wiring a pump with no plug, the green (or green/
yellow) wire is ground, and the other two are line (live). 
Do not allow the pump to run dry (without liquid). This pump is 
not submersible; operate it only in the in-line mode. Do not put 
the pump into liquid. Install the pump in a dry area, protected from 
splashing. This pump is not self priming; it must be installed so that 
the pump head (volute) is flooded when the pump is started. That 
is, the inlet of the pump must be below the level of the surface of the 
liquid being pumped (Figure 1). 
Do not restrict the intake side of the pump. Connections on the intake 
side should not be of smaller inside diameter pipe or tubing or hose 
than the intake inside diameter of the intake thread designation. If 
reduced flow is required, install a valve or other restriction device on 
the discharge side. When using a valve, the pump can be throttled 
to provide various flow rates and pressures without harming the 
motor or the pump parts.

SPECIFICATIONS

MODEL

INTAKE  SIZE

DISCHARGE  SIZE

MOTOR

MOTOR

TYPE**

MAX. 

PSI

SHUTOFF 

HEAD

(FT.)

GALLONS PER MINUTE @ HEAD

DIMENSIONS

WEIGHT

PACKED

(LBS.)

VOLTS

HERTZ

PHASE H.P. WATTS AMPS

1'

3'

6'

9'

15'

18'

24'

H

W

L

4-MD*

1/2” 

FNPT

1/2” 

MNPT

115

60

1

1/12

213

2.4

OPEN-

FC

10.2

23.7

11.5 11.0 10.0

9.1

6.5

4.7

--

4.3”

4.0”

8.9”

8.5

214

3.1

50

7.1

16.4

13.3 12.7 11.8 10.0

4.3

--

--

5-MD

1/2” 

FNPT

1/2” 

MNPT

115

60

1

1/8

200

2.1

OPEN-

FC

PSC

15.0

34.6

15.1 14.6 13.3 12.5 10.6

9.6

7.3

5.6”

5.4”

8.3”

9.3

155

1.9

50

9.7

22.4

13.8 13.3 12.3 11.2

8.8

7.3

--

*Not recommended for 50Hz operation. Possible motor overheating will occur in some applications.

**Open = Open motor, FC = fan cooled, PSC = permanent split capacitor

NOTE: Data shown is catalog performance. 230V data is the same as 115V for each frequency.

FIGURE 1

Reviews: