Littfinski Daten Technik SA-DEC-4-MM-F Operating Instruction Download Page 1

L

ittfinski 

D

aten

T

echnik (

LDT

)

 

Operating Instruction

 

 

 

 

 

Multi-Digital

 

                                                                                

  

 

4-fold switch decoder 

from the 

Digital-Professional-Series 

!

 

 

SA-DEC-4-MM-F 

Part-No.:

 210312 

 

 

(With possible external power supply)

 

 

>> finished module << 

 

Compatible to Märklin-Motorola-Format: 

 

(e.g. 

Märklin-Digital

 

[

Control Unit

Central Station 1

 

und 

2

], 

Intellibox

EasyControl

ECoS

KeyCom-MM

DiCoStation

EDiTS

EDiTS pro 

and others) 

 

For digital control of: 

 

 

consumers up to 2 Ampere on each output

 

(e.g. illumination, disconnection of track sections from 
power). 

 

jammed turnout- and signal drives 

(drives with integrated end switch). 

 

 
This product is not a toy! Not suitable for children under 14 years of age!  
The  kit  contains  small  parts,  which  should  be  kept  away  from  children  under  3! 
Improper use will imply danger of injuring due to sharp edges and tips! Please store 
this instruction carefully. 

 

 

 

 

 

 

red point 

 

 
 
 
 

Introduction/Safety instruction: 

 

You  have  purchased  the  4-fold  switch  decoder 

SA-DEC-4

  for 

your model railway as a kit or as finished module. 
The 

SA-DEC-4

  is  a  high  quality  product  that is supplied  within 

assortment of 

L

ittfinski 

D

aten

T

echnik (

LDT

). 

 

We wish you having a good time using this product. 

 

The  switch  decoder 

SA-DEC-4

  of  the 

Digital-Professional-

Series

 

can be easily installed and used on your digital railway. 

 

The 

colored  point

  on  the 

receiver  device

  indicates  to  which 

digital system the decoder can be adapted. 

 

In  case  the 

receiver  device

  is  marked 

red

  the  decoder  is 

suitable for 

Märklin-Digital~ 

respectively for

 Märklin-Motorola 

layouts. 

 

In case the 

receiver device

 is marked 

yellow

 the 

SA-DEC-4

 will 

be  suitable for  the 

DCC  Data  format,

  used  for instance  at the 

systems  of 

Lenz-Digital  Plus,  Arnold-,  Märklin-Digital=, 

Intellibox, TWIN-CENTER, Roco-Digital, EasyControl, ECoS, 
KeyCom-DC, Digitrax, DiCoStation 

and

 Zimo

 

The decoder 

SA-DEC-4

 is 

multi digital

 and can be installed to 

the 

Intellibox

 without any problems. 

 

The finished module comes with 

24 month warranty

 

  Please read the following instructions carefully. Warranty will 

expire due to damages caused by disregarding the operating 
instructions. 

LDT

 will also be not liable for any consequential 

damages caused by improper use or installation. 

  Also, note that electronic semiconductors are very sensitive to 

electrostatic  discharges  and  can  be  destroyed  by  them. 
Therefore, discharge yourself before touching the modules on 
a grounded metal surface (e.g. heater, water pipe or protective 
earth  connection)  or  work  on  a  grounded  electrostatic 
protection mat or with a wrist strap for electrostatic protection. 

Connecting  the  decoder  to  your 
digital model railway layout: 

 

 

Attention:  Before  starting  the  installation  switch  off  the 
drive  voltage  by  pushing  the  stop  button  from  the 
command station or disconnect the main supply.

 

 

The decoder receives the

 digital information 

via the

 

clamp 

KL2

Connect the clamp with a rail or even better connect the clamp 
directly to the command station or to a booster assuring supply 
of digital information free from any interference. 

 

Pay  attention  to  the  mark  at  clamp 

KL2.

  The  color  markings 

'

Black/Schwarz

'  and 

'Red/Rot'

  next  to  the clamp  are  used for 

Arnold-Digital (old) 

and

 Märklin-Digital=.

 

 

Other systems are using the letters '

J

' and '

K

'. 

 

If  you  use  the  decoder  for  a 

Märklin-Digital~ 

respectively

 

Märklin-Motorola 

installation please attend to the colors marks 

'red/rot' 

and 

'brown/braun'

 

The decoder receives the 

voltage-supply

 via the two-pole 

clamp 

KL1

. The voltage shall be in the range of 12 to 18V~ 

(alternating voltage output of a model railway transformer) or 15 
to 24Volt = (direct voltage output of an insulated power supply 
unit). 

 

Now connect the consumers (e.g. illumination, motors or turnout- 
and signal coils) to the outputs 1 to 4. The contact marked 

'COM' 

is the common connection for the bistable relay. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 

Programming the decoder address: 

 

For  programming  the  decoder  address  you  have  to  connect  a 
consumer to the output 1. As it is possible to hear the switching 
of  the  bistable  relay  the  connection  of  a  consumer  is  not 
mandatory. 

 

  Switch on the power supply of your model rail way.

 

 

  Depress  the  programming  key  S1.  Do  not  touch  the 

integrated circuits of the pc-board because any electrostatic 
discharge can destroy the IC`s.

 

 

  The relay connected to output 1 will now switch automatically 

every 1.5 seconds. This indicates that the decoder is in the 
programming mode.

 