23/48
5.
COMMISSIONING
5.1.
Operating materials
Lubricant
The grease used on the floor saw is called "Energrease LS2 BP". (Lithium-saponified multi-purpose grease
from NLGI Grade 2 in accordance with DIN 51818 / NLGI GC – LB Grade 2)
Water
The water pressure in the supply line must not exceed 5 bar. If necessary, use a pressure reducer.
V-belt
Use full sets (4 pcs.) model XPZ950.
Electrical connection
Stable power source, three-phase alternating current with the operating voltage of 400 V / 16 A as specified on
the type plate and the corresponding protection with a fault current circuit breaker (ground fault circuit
interrupter/RCD).
5.2.
Tools (saw blade)
NOTICE
Selecting the tool
Rotary tools with a maximum speed less than the nominal speed of the machine may not be used.
Defective or cracked tools must be replaced immediately.
Selecting the saw blade
See Chapter 8 Tools
Storing tools
The tools used must be protected from moisture. The segments installed around the saw band must be
protected from damage.
Saw blade speeds
To achieve the optimum cutting performance, the saw blade speed must be adjusted to the material to be
cut.
5.3.
Establish power connection
Procedure
•
Check the plug for wire damage
•
Fully unroll the cable and lay it safely
•
Establish power connection
•
Check the functionality of the ground fault current interrupter/RCD in the switch cabinet