Dive Computer
User Manual
Liquivision Products, Inc
-
35
-
Revision 3.2 Software 2.58
This allows you to control the minimum time of surface interval before next dive is classified as new
dive. If you stay on the surface for shorter time than the specified interval, your next descent will still
be considered a part of the previous dive, and both descents will be logged as one dive. You can control
this value in increments of 1 minute. Minimum value is 0, maximum – 30 minutes.
7.6. Minimum Surface Interval
If you tap into this menu setting, you will see basic information concerning
your device, such as type, hardware version, software version, etc.
7.7. Status
The type or capacity of the battery is needed to accurately estimate the remaining dive time.
7.8 Battery Type
There are three battery types available:
•
White-ER14335M (Disposable Lithium Battery)
•
Blue-ER17335M (High Capacity Disposable Lithium Battery)
•
White with green text-LFP-123A (Rechargeable Lithium-Iron-Phosphate Battery)
You can find more information about the different battery types in the section on
Important
Information About XEO Batteries.
This menu item allows you to select battery meter style either in battery symbol graphic or in battery
voltage value. The default setting is “Symbol”.
7.9 Battery Meter
Battery Meter: Symbol
Battery Meter: Voltage
This menu item runs the battery test for the selected battery type and displays the estimated remaining
dive time. This test will take approximately 1 minute. During the battery test, you will see the screen
light up progressively with white pixels, to provide a battery reading when the unit is at maximum
battery consumption.
7.10 Battery Test