Page 84 of 130
Operating instructions
4point light 10W (V 4.58)
8.7 Contact
The output voltage is a good indicator for the quality of the coupling of the current
electrodes. “Contact” will give an estimation of the output voltage that is necessary to
establish the preset constant output current at the AB-electrodes.
WARNING
Voltage at the electrodes A and B
Activation of the menu item “Contact” will switch ON the transmitter. Touching the
electrodes A and B may result in an electric shock.
→
Do not touch energized electrodes A and B
→
Make sure that the instrument is not working before touching or
relocating the electrodes.
VES MAP RMT TOM MON
CONTACT SP DELETE
SETTINGS MISC INFO
Battery: 5.52V
Fig. 8.87: Main menu
1.
Select “CONTACT” from the main menu with [
] and [
]
2. Confirm selection with [RET]
Output Voltage
0.31 Hz 1.0mA
164.23V
164.23 kOhm <ESC>
Fig. 8.88: Contact menu
– continuous display of the transmitter voltage
Menu item
Function
Output Voltage:
Output voltage
0.31 Hz:
Output frequency (selectable)
1.0 mA
Output current (selectable)
164.23 V
Output voltage (displayed)
164.23 kOhm
Contact resistance
Tab. 8.64: Contact
– menu items