Lippert Components Project 2000 12600 Series Owner'S Manual Download Page 8

Rev: 11.21.2014

Page 8

Euro Loft Bed Lift by Project 2000 Owner's Manual

11. 

Place the limit switch correctly, making sure the bed locates against it perfectly when it comes to its 

highest position.

NOTE: 

For bed lifting systems where the highest position is right under the vehicle roof or when the highest 

position more than 1500 mm from the floor, it is necessary to mount at least 2 opposed safety belts 

with internal micro-switch with normally closed contact.

NOTE: 

The micro-switch must be connected in series with the limit switch. There must be at least 2 opposed 

safety belts.

12. 

Bring the bed lifting system to its lowest position, making sure the stabilizer runners are in a perfectly 

vertical position and will not jam.

13. 

Fix the stabilizer runners with suitable screws (we recommend at least 3.8x20 screws) in the middle 

channel of the runner at a maximum distance of 10" from each other. 

NOTE: 

Make sure the screw head does not protrude too much, otherwise it will hit and damage the 

stabilizer. Adjust the stabilizer and fix the m4x6 screws with some “soft” thread-locker.

14. 

Then install the electrical components (Fig. 7) and program the system as illustrated in the installation 

and programming manual (ONLY AVAILABLE FOR SERVICE CENTERS)

NOTE: 

It is forbidden to use the bed while the vehicle is running, as the bed must be locked with safety 

belts.

NOTE: 

Each bed lifting system model was designed and developed to reduce or eliminate any risks related 

to cutting and tangling. The installer must however mount the system avoiding any risk factors/

elements such as sharp edges, curls, etc.

15. 

After finishing installation, make sure the bed lifting system has no clearances and movements and the 

bed is parallel to the floor.

NOTE: 

In the event it is necessary to operate the bed lift system manually through the handle, it is 

compulsory to carry this operation without disconnecting the wires from the motor unit to the 

control unit.

NOTE: 

Never disconnect the wires from the motor unit to the control unit for a manual start of the bed lift 

system.

Electrical

• 

With mechanical encoder.

The circuit board is a controlling device with:

• 

DC 12 V power, maximum 25A.

• 

Free, normally closed contact end-of-stroke signal input.

• 

DC 12 V, maximum 25 A motor output, with polarity control.

Fig. 1

Summary of Contents for Project 2000 12600 Series

Page 1: ...Rev 11 21 2014 Page 1 Euro Loft Bed Lift by Project 2000 Owner s Manual Euro Loft Bed Lift by Project 2000 OWNER S MANUAL...

Page 2: ...ures 6 Movement and Transport 6 Prior to Installation 7 Installation 7 Mechanical 7 Electrical 8 Mechanical Encoder 9 Circuit Board Connection 9 Assembling and Harnessing Procedure for the Encoder Uni...

Page 3: ...cribes the system purpose and use based on its project and technical features it provides instructions for transport proper and safe installation mounting adjustment and use It provides information fo...

Page 4: ...t laws and regulations Use in case of primary power defects Use with serious maintenance negligence Use in breach of the maximum capacity values indicated in this manual Use without safety fall protec...

Page 5: ...led way other than described in this manual or in case of non compliance with maintenance and safety rules Product knowledge and compliance with the instructions provided in these documents are prereq...

Page 6: ...f the goods and to make sure the product is perfectly preserved and intact Make sure the system has no evident damage and the delivery is complete and write any possible problem on the shipping docume...

Page 7: ...Picture A 2 in a suitable position i e the highest position the system will reach making sure the belts are aligned with the runners and taking care of the minimum distance to be kept between the slid...

Page 8: ...x6 screws with some soft thread locker 14 Then install the electrical components Fig 7 and program the system as illustrated in the installation and programming manual ONLY AVAILABLE FOR SERVICE CENTE...

Page 9: ...rotates in the direction shown by the arrow printed on the black plastic cover Connect the ORANGE wires to the Down end of stroke of the mechanical encoder and connect the YELLOW wires to the Up end...

Page 10: ...until the desired position is reached Remember to fasten the 14mm bolt How to correctly check the end of stroke connection 1 Control panel by pressing the UP button the bed must go up and it must go d...

Page 11: ...Pin 5 Motor Grey MOT1 DC 0 12 V Pin 4 Motor Brown Not used Pin 3 Not used Not used Pin 2 Not used Not used Pin 1 Not used The motor has a 5 pole connector for a female movable connector represented in...

Page 12: ...Rev 11 21 2014 Page 12 Euro Loft Bed Lift by Project 2000 Owner s Manual Fig 6...

Page 13: ...ructure developed to this purpose and its stroke is limited by two ends On the upper side the stroke is limited by an end of stroke sensor On the lower side the limit is represented by the lowest posi...

Page 14: ...non observance of the rule could modify the lowest stop position The different models have been designed and manufactured keeping in mind all the main standards of safety to reduce and or cancel any e...

Page 15: ...erated neither with any objects nor with hands Before starting the vehicle engine and driving always make sure the bed lifting system is in its highest position and the safety belts are fastened exclu...

Page 16: ...nd sorting the components hand them to authorized companies for disposal Disassembling and demolition operations shall be performed by skilled and authorized staff Bed lifting system components overha...

Page 17: ...0 guarantees the bed lifting system components for 24 months after purchase Defective parts shall not be tampered with and they shall be returned together with the serial number indicated on the plate...

Page 18: ...Rev 11 21 2014 Page 18 Euro Loft Bed Lift by Project 2000 Owner s Manual Tab A Tab B...

Page 19: ...ottom part of the mechanical end of stroke stops Is the system user s manual available Five Yearly Check Date __________ Number of Cycles _________ Yes No General check of the system by an authorized...

Page 20: ...d so that they can be correctly identified despite wear Are there any clearances in the belt roller s and the gear motor coupling Is the gear motor perfectly working in all of its mechanical functions...

Page 21: ...d so that they can be correctly identified despite wear Are there any clearances in the belt roller s and the gear motor coupling Is the gear motor perfectly working in all of its mechanical functions...

Page 22: ...consent from an authorized LCI representative has been provided Any unauthorized use shall void any applicable warranty The information contained in this manual is subject to change without notice an...

Reviews: