Manual Override
The LCI Level Up Automatic Leveling System can be manually operated with an electric drill. In the event of
electrical or system failure, this manual method of extending and retracting the jacks can be used. See the
instructions below.
NOTE: Unhook the power unit motor from the power source prior to attempting the manual override
procedure.
1. Locate the valves that are paired with the leveling jacks to be manually overridden. Leveling jack valves
are located on the manifold (Fig. 8).
2. Using a 5/32” hex wrench, open the valve by turning the manual override set screw clockwise (Fig. 9A).
3. Remove protective label (Fig. 10A) from power unit to reveal the manual override coupler.
4. Using an electric drill with a 1/4" hex bit, insert the hex bit into the manual override coupler to manually
operate the Level Up system (Fig. 11).
A. Run the drill forward (clockwise) to retract the leveling jack (Fig. 11A).
B. Run the drill in reverse (counterclockwise) to extend the leveling jack (Fig. 11B).
5. Make sure to turn the manual override set screw on the valve (Fig. 12A) back to the counterclockwise
position after extending or retracting the jacks.