Rev: 11.19.20
Page 21
CCD-0002764
Safety Belt Harness
The safety belt harness (Fig. 36A and 36B) will need to be fastened one side to the bed frame and the other
side to the ceiling of the unit, on both sides of the bed frame. In some cases it’s better to have the female
plug (Fig. 36B) on the ceiling, in other cases it’s better to have it on the bed frame. Actual fastening methods
and materials may be dictated by the project plans or applicable local codes.
Fastening and wiring methods may also be directed by a professional engineer. Usually a plate is used to
fasten the male side (Fig. 36A) to a surface.
An electrical connector on the female plug (Fig. 36B) will need to be wired to a relay positioned between the
power supply and the control switch of the bed, so if the safety belt is connected the bed will not move.
1.
Make sure the bed lift is in the highest retracted position.
2.
Install the safety belt harness to the bed and ceiling on both sides of the bed.
3.
Wire the safety belt harness female plug (Fig. 36B) ends into a relay between the power source and the
power controller connector on the main wire harness.
NOTE:
Wiring and relay must meet all appropriate electrical and installation codes.
Fig. 36
A
B
A
B