Operating instructions
Multipurpose Gyration Harrow UKD L/S
23 - 28
06.07.2004 / 00
•
Check the level of liquid grease in the gearbox via the
corresponding plug (Fig. 11). This operation must be carried out
when the machine has already been running for a few minutes
and the grease has warmed up and become distributed evenly.
Then check the grease level with a dipstick (grease level should
be 2.5 cm). If necessary, top up liquid gear grease (based on
sodium bicarbonate - type GP 00).
•
In case of machines with angular gear, the oil level can
additionally be read on the inspection glass. Oil level must be at
least at the half in the inspection glass (in the angular gear, use
gear oil GX 85-90A).
Amounts of liquid grease for gearbox
•
Check whether the tines are tightened, and retighten the screws,
if necessary. Replace damaged screws immediately! (See
chapter "12. Replacement of the tines")
UKD Type
L-90
L-110
L-125 L-140 L-155 S-130 S-150 S-190
Quantity
Liquid
grease type
GP00
(kg)
4,8 5,8 7,0 8,0 9,0
Oil plug
Fig.11