Installation Guide Linear Motors
ENG
Page 14 / 32
P10-54 / P10-54-D24/25/25S
NTI AG / LinMot
4 Motor Cable
Do not connect or disconnect motor when there is power on the servo drive.
Use only original LinMot cable. Cables from other sources must be checked precisely
before commissioning.
Incorrect connections can destroy the drive and stator.
4.1 Technical Data
The motor series P10-54 use various types of cables, which are used for power supply and signal power. All
cables are high-flex cables (suitable for trailing chains) and are used for fixed and moving applications.
Power cable
Sensor cable
Type
KPS07-04/02
KSS05-02/08
KSS05-02/13
Used for
PS10-54
PS10-54-D2x
PS10-54
PS10-54-D2x
Minimum bending
radius for fixed
installation
70 mm
(2.76 in)
45 mm
(1.75)
45 mm
(1.75)
Minimum bending
radius when moving
140 mm
(5.52 in)
No torsion
90 mm
(3.54 in)
No torsion
90 mm
(3.54 in)
No torsion
Max. Cable length
30 m (may be limited by Servo Drive)
Approval
UL / CSA 1000V / 300V
UL / CSA 300V
UL / CSA 300V
Material
Wire isolation: PES
Jacket: PUR
Wire isolation: TPE
Jacket: Special TPU
Wire isolation: PE
Jacket: PUR
Oil resistance
very good
very good
very good
Chemical resistance
(to acids, alkalis,
solvents, hydraulic
fluid)
good
good
good
Outdoor durability
very good
very good
very good
Flammability
flame retardant
flame retardant
flame retardant