3 Installation instructions
Operating conditions
Maximum ambient temperature limits:
•
0 °C
1)
…80 °C
Internal temperature sensor error occurs at:
•
120 °C
1)
Lower temperatures on request.
Assembly of the linear motor
Please attend to the safety instructions in chapter 2 during the assembling!
Clean the slider with a paper towel.
Lubricate the slider.
Sliders with a length of more than 500 mm are
lubricated with a grease quantity of 4 g (approx.
½ hazelnut) per meter. Shorter sliders are
inserted without lubrication.
The grease can be applied by hand or with a
soft paper towel.
Always observe the specified grease
quantity. Over lubrication leads to a
gumming of the grease, which
appears particularly at higher
operating temperatures!
Insert the slider in the defined direction (see
next assembly step).
Large magnetic attraction forces
(Observe warning notice from page 5)!
If necessary, cover obvious iron constructions
with non-magnetic material (e.g. wood).