L
i
n
M
o
t
Motion Control SW
Header
0
06Dxh: Setup Encoder Cam On Rise Trigger Event
With Delay Counts, Amplitude scale and Length
UInt16
-
1. Par
2
Curve ID
UInt16
1..100
2. Par
4
Curve Start Delay Count
SInt32
1 Incr
3. Par
8
Amplitude Scale
Sint16
0.1 %
4. Par
10
Curve length in Counts
SInt32
1 Incr
Setup in the event handler to start a cam curve on the rising trigger event with the specified
curve ID and the specified delay counts to specified target position in specified counts. The
specified curve ID is written to the RAM value of UPID 154Ah, and the specified cam start
delay is written to the RAM value of UPID 154Ch. Use the infinite cam length (UPID1527h)
for triggered cam motions.
4.3.64
Setup Encoder Cam On Falling Trigger Event With Delay
Counts, Amplitude scale and Length (06Exh)
Name
Byte
Offset
Description
Type
Unit
Header
0
06Exh: Setup Encoder Cam On Fall Trigger Event
With Delay Counts, Amplitude scale and Length
UInt16
-
1. Par
2
Curve ID
UInt16
1..100
2. Par
4
Curve Start Delay Count
SInt32
1 Incr
3. Par
8
Amplitude Scale
Sint16
0.1 %
4. Par
10
Curve length in Counts
SInt32
1 Incr
Setup in the event handler to start a cam curve on the rising trigger event with the specified
curve ID and the specified delay counts to specified target position in specified counts. The
specified curve ID is written to the RAM value of UPID 154Ah, and the specified cam start
delay is written to the RAM value of UPID 154Ch. Use the infinite cam length (UPID1527h)
for triggered cam motions.
4.3.65
Start VAI Encoder Position Indexing (070xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
070xh: Start VAI Encoder Position Indexing
UInt16
-
1. Par
2
Target Position
SInt32
0.1 um
2. Par
6
Maximal Velocity
UInt32
1E-6 m/s
3. Par
10
Acceleration
UInt32
1E-5 m/s
2
4. Par
14
Deceleration
UInt32
1E-5 m/s
2
Changes to the VAI encoder position indexing mode, the actual encoder count is to the target
position. To stop the indexing mode use one of the commands (008xh), (07Exh) or (07Fxh).
4.3.66
Start Predef VAI Encoder Position Indexing (071xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
071xh: Start Predef VAI Encoder Position Indexing
UInt16
-
1. Par
2
Target Position
SInt32
0.1 um
Page 40/91
User Manual Motion Control SW / 06/12/2013
NTI AG / LinMot