72
Relay2Follow
mode
Independent: Open the door independently with Relay1
Synchronous: open the door at the same time as Relay1
Asynchronous: Relay1 opens after a period of time Relay2 opens
Asynchronous
delay
The user can set the asynchronous door opening delay time of
Relay1 and Relay2, the default is 1 second
RFID card format Supported access control card format
Wiegand format
Supported Wiegand access card format
Wiegand mode
Optional input port or output port
Enable Virtual
password
After enabling, the correct password will be included in the
consecutively entered numbers to open the door
Enable Card
Reader
Enable or disable card reader for RFID cards.
Card Reader
Working Mode
Set ID card stats:
Normal: This is the work mode, after the slot card can to open the
door.
Card Issuing: This is the issuing mode, after the slot card can to add
ID cards.
Card Revoking: This is the revoking mode, after the slot card can to
delete ID cards.
9.39
EGS Setting >> Relay
Picture 61 - Relay
Table 35 - Relay
Field Name
Explanation
Relay Status