Link TL-16000CL Instruction Manual Download Page 1

 

1

  / 

21

    (ver.0.52)

 

 

 

Model: TL-16000CL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

TAKENAKA SENSOR GROUP

 

 

TAKENAKA SYSTEM CO.,LTD.

 

 

 

 

□  H e a d   O f f i c e  86-66 Nomizo-cho Otsuka Yamashina-ku 607-8135 Kyoto JAPAN 

 

 

TEL:+81-75-593-9300    FAX +81-75-593-9790 

□  C a m e r a   D e p t .    

4F Matsumasa Bld.1-17-14 Ogaya Otsu Shiga 520-2144 JAPAN 

 

 

TEL:+81-77-545-4331    FAX +81-77-545-4335 

□  Inspection System Dept.  86-66 Nomizo-cho Otsuka Yamashina-ku 607-8135 Kyoto JAPAN 

 

 

TEL:+81-75-593-9300    FAX +81-75-593-9790 

□  T o k y o   O f f i c e 

2F MK Bldg. 2-2-19 Sotokanda Chiyoda-ku 101-0021 Tokyo JAPAN     

  

TEL :+81-3-3255-0361

     

FAX:+81-3-3255-0362 

TAKENAKA SYSTEM CO.,LTD.              URL    http://www.takex-system.co.jp/ 
TAKENAKA SENSOR GROUP                URL    http://www.takex.co.jp/ 

            Line scan camera 

              Instruction Manual

 

 

Summary of Contents for TL-16000CL

Page 1: ...Otsu Shiga 520 2144 JAPAN TEL 81 77 545 4331 FAX 81 77 545 4335 Inspection System Dept 86 66 Nomizo cho Otsuka Yamashina ku 607 8135 Kyoto JAPAN TEL 81 75 593 9300 FAX 81 75 593 9790 T o k y o O f f...

Page 2: ...t Assignment 6 6 External Device Layout 6 7 Initial setting 7 7 1 Operational setting of the camera 7 7 1 1 SYNC setting 7 1 2 EXP mode setting 7 2 FFC Function setting 8 7 3 Gain control 9 7 3 1 ADC...

Page 3: ...rcuit is incorporated Reduction in size and weight has been realized by adopting unique circuit and mechanism design 3 Internal Configuration High sensitive and high speed CMOS sensor with 16 384 effe...

Page 4: ...unt ke 23 typical value Output ununiformity 10 standard at 50 of saturation output on the element Dynamic range 60 dB on the element Flange focus 19 55 mm Power supply 12V 0 5V 0 5A or less Operationa...

Page 5: ...4 Y2 17 Y2 5 Yclk 18 Yclk 6 Y3 19 Y3 7 100 20 terminated 8 Z0 21 Z0 9 Z1 22 Z1 10 Z2 23 Z2 11 Z clk 24 Z clk 12 Z3 25 Z3 13 Shield 26 Shield Medium and Full Configuration Connector 5 Camera Interface...

Page 6: ...N Port G 12289 16383 ODD Port H 12290 16384 EVEN Port bit 8 bit Port bit 8 bit Port D0 D0 Port F4 F4 Port D1 D1 Port F5 F5 Port D2 D2 Port F6 F6 Port D3 D3 Port F7 F7 Port D4 D4 Port G0 G0 Port D5 D5...

Page 7: ...tocol P 12 13 Refer to Serial Communication Protocol P 10 11 At Hyper terminal cfg The following list is obtained 7 1 Operational setting of the camera 7 1 1 Synchronization setting Sync N Sets the ca...

Page 8: ...the target gray level of video level Make the level adjustment by changing lens aperture or exposure time using plain white target sample Note Make the adjustment under the condition that a foreign ob...

Page 9: ...log gain of the camera 0 one fold 1 four fold It is recommended to use 7 3 1 ADC gain setting as the four fold value of Analog gain is too sensitive and is more likely to worsen the standard deviation...

Page 10: ...nnector when applying current to the equipment It causes the equipment to malfunction When disposing of the equipment delegate the task to the industrial waste disposal contractor And execute the disp...

Page 11: ...38 3 4 3 0 3 6 4 M 4 D ep th 100 1 0 0 M7 2 P 0 7 5 D e pt h 1 0 78 15 19 55 22 6 2 80 8 0 1 1 1 7 5 17 5 17 5 70 2 M 6 D ep th8 1 1 4 M 4 D ep th M ax 6 34 82 1 4 20UNC D ep th8 8 I maging plane Maxi...

Page 12: ...xp o su re du r in g t he pe r io d o f t he p u ls e w i dt h o f E XT S Y NC CC 1 Mi m im u m ex p os u re t i me 5 se c No te th a t th e m i ni mu m p e ri o d of EX T S YN C i s 2 8 6 7 se c i n...

Page 13: ...8 18 6 S8 18 8 S8 18 4 S4 09 9 S4 09 7 S8 18 3 S8 18 7 S8 18 5 S8 18 9 S8 19 1 S4 10 0 S4 09 8 S 1 2 29 0 S 1 2 29 2 S 1 6 37 6 S 1 6 38 0 S 1 6 37 8 S 1 6 38 2 S 1 6 38 4 PIX EL D ATA POR T H OS 2 PI...

Page 14: ...re time Time explt N CR Get Gain Position gainpos CR Non 1 2 Gain position Get the Gain position Set Gain Position gainpos A CR A 1 2 Gain position OK Set the Gain position Get chXgainA chXgainA CR X...

Page 15: ...on 0 255 Getting setting Note 2 Value set shd_dat N CR N 0 255 OK Data value setting shd_dat CR Non 0 255 Data value getting Taget Level for shd_to N CR N 0 255 OK Correction targeted level black leve...

Page 16: ...s Hyper Terminal 2 The windows will appear with the picture below 3 When the next picture appears enter any name e g GMA_RS232C Then click the OK button 4 When the next picture appears select COM on C...

Page 17: ...ch items as follows 9600 8 None 1 Non Then click the OK button 6 The next picture will appear 7 Select File Properties Network transmission setting Baud rate 9600 bps Data length 8 bit Start bit 1 bit...

Page 18: ...ngs tag 9 When the next picture appears click the ASCII Setup button 10 When the next picture appears select each items as follows 0 0 blank blank Then click the OK button 11 The screen display will r...

Page 19: ...send it out If OK is displayed on the screen communication processing has been completed 13 Select Start Programs Accessories Communications Hyper Terminal 1 when to launch the Hyper terminal again wi...

Page 20: ...position X arbitrary numeral indicating Channel Gain position GAIN position of the camera Channel Channel to specify the GAIN control device for each CCD output line EEPROM EEPROM incorporated in the...

Page 21: ...r e g Input error Input value is beyond the setting range Input gainpos 96 Output NE e g Input error Input value is beyond the setting range Input ch1gain1 2000 Output NE NC is returned in case of inp...