Setup Menu
110
This setting should be the Air Fuel Ratio that corresponds to the AFR Maximum voltage.
The Valid Range is 0.0 to 24.0 in .1 increments.
Access from the Controller:
From the
, press the “SETUP” button. Press the “DOWN” arrow button repeatedly until the AFR
Setup Menu selection is highlighted, and then press the “ENTER” button. Press the down arrow until the "AFR
Max Value" selection is highlighted and then press the "ENTER" button. Use the “LEFT” and ”RIGHT” arrow
buttons adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC” button to exit
with no change.
Access from the Computer Program:
From the
, press the "Setup" button. The "AFR Maximum Value" setting is found in the "AFR Input
Setup" dialog box under the "Air Fuel Ratio" Tab. Click the "UP" and "DOWN" arrow buttons or type in any
numeric value in the valid ranges shown above.
7.9
Relay1 and Relay2 Setup Menus
The Relay1 output is a NCC-001 controlled ground output. The Relay2 output is a NCC-001 cont12 volt
output.
The following options are found in both the Relay1 and Relay2 setup menus, which can be accessed by the
"SETUP" button on the main screen or through the Relay1 and Relay2 buttons in the computer software. The
control options found in these menus are used to determine the parameters for enabling either Relay1 or Relay2.
Any combination of enabling control options can be used to enable Relay1 and Relay2.
Arming Input Control Option
If this option is enabled, the selected Relay output is controlled by the state of the Arming Input and any other
control options that are enabled.
Access from the Controller:
From the
, press the “SETUP” button. Press the “DOWN” arrow button repeatedly until the desired
Relay Menu is highlighted and then press the “ENTER” button. Press the "ENTER" button to select the "Act Input
Summary of Contents for NCC-001
Page 5: ...Introduction Part I...
Page 11: ...Parts List Part II...
Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...
Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...
Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...
Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...
Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...
Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...
Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...
Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...
Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...
Page 55: ...Getting to Know the User Interface Part IV...
Page 59: ...Global Menu Setup Options Part V...
Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...
Page 85: ...Setup Menu Part VII...
Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...
Page 161: ...Appendices Part IX...