background image

PERS-2400

PERSONAL

EMERGENCY

REPORTING

SYSTEM

Installation Instructions

PRODUCT DESCRIPTION

The PERS-2400 Console is a supervised wireless emergency reporting product designed for medical
alert applications. The table-top or wall-mount Console provides “pushbutton” emergency assistance to
anyone who desires additional security and peace of mind.
The Console has three emergency functions: emergency, fire, and activity. The emergency zone can be
triggered by the large EMERGENCY button on the face of the Console or with various models of wireless
transmitters. The fire zone can be triggered by wireless smoke alarms. The optional activity timer can be
set for 8, 12 or 24 hour operation. If the time expires before an activity transmitter is activated, or the
HOME button is pressed on the Console, the inactivity will trigger the emergency zone. For the visually
impaired, each button on the Console is molded with braille characters to identify the button’s function.
The Console is programmed using Linear’s RA-2400 remote access software. For details on
using the RA-2400 software, refer to the software’s built-in help file.
The Console can receive signals from Linear’s wireless battery-powered transmitters sending DX or DXS
format signals. Up to 16 individual transmitters can be used with the Console. Activating a transmitter
causes the Console’s built-in digital communicator to send the appropriate alarm report to the central
monitoring station via the standard telephone network. In addition to the central station report, audible
and visual indications occur and the alarm relay energizes during an emergency activation. 
If  the  optional  Model  VB-4  voice  board  is  installed,  the  Console  will  “talk”  to  the  user.  The  digitally
synthesized, actual human voice, will sound “emergency”, “fire”, “timer done soon”, and other system
operation,  setup,  and  supervisory  prompts  from  a  38 word vocabulary. In addition, the  voice board
supports 2-way automatic, 2-way manual, and 1-way listen-only audio emergency communications with
central station monitoring personnel using the Console’s built-in high-sensivity microphone and speaker.
Supervised transmitters regularly send status reports to the Console and low battery reports when their
batteries are low. When the Console receives a low battery report, the TROUBLE indicator flashes. If the
Console fails to receive a status report from a transmitter for a period of 24 hours, the TROUBLE indicator
will light. All supervisory conditions can sound a local annunciation and be reported to the central station.
The Console’s digital communicator can route calls to three telephone numbers: primary, secondary, and
supervisory. General reporting codes and individual sensor reporting codes are programmable for the
4x2 format. Alternately, Ademco Contact ID may be selected for the communicator reporting format.
Powered by a low voltage plug-in transformer, the Console has provisions for a recharagable backup
battery  for  operation  during  AC  power  outages.  A  backup  battery  disconnect  switch  allows  for
out-of-service storage of the Console without discharge of the battery. The battery is recharged and
supervised by the Console. If the backup  battery becomes  low the POWER light will flash and the
condition can be reported to the central station.

OPERATION SUMMARY

A  variety  of  Linear’s  transmitters  can  be  used  with  the  Console.  Supervised  and  non-supervised
transmitters in DX or DXS format can be used. The Consoles three zones function as follows:
EMERGENCY
Portable, supervised and non-supervised, pendant, belt-clip, or wristband type transmitters (Models
DXT-41,  DXT-42,  DXT-61A,  DXS-21,  DXS-23,  DXS-62,  DXS-63)  and  stationary,  supervised  Model
DXS-31 transmitters are used for medical alert applications. When this type of transmitter is triggered,
the Console sounds a two-tone siren and an emergency report will be sent to the central station. The
emergency zone can also be triggered by pressing the EMERGENCY button.
FIRE
Supervised Model DXS-72 wireless photoelectric smoke alarms can trigger the fire zone. When a smoke
alarm is activated, the Console sounds a repeated series of three beeps and a fire report will be sent to
the central station.
ACTIVITY
Supervised, switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) can be used
for ensuring human activity. The motion detector will monitor human presence in a room. The contact
activated transmitter can be wired to a pushbutton or switch for manual activity monitoring. As long as a
signal is received at least once every 8, 12, or 24 hours (programmable) an alarm will not be triggered.
15 minutes before the programmed time expires, the HOME indicator will start blinking and a low pitched
beep will sound every ten seconds. The activity timer can be reset with a signal from one of these transmitters
or by pressing the HOME button on the Console. Failure to receive a signal within the programmed time period
will cause the Console to sound the two-tone emergency siren and report an inactivity alarm to the central
station. The activity timer can be turned on or off at the Console or through programming.

SYSTEM OVERVIEW

FRONT PANEL FEATURES

REMOVING BOTTOM COVER

CONSOLE BOTTOM FEATURES

OPTIONAL MODEL VB-4 VOICE BOARD INSTALLATION

BACKUP BATTERY

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

OPTIONAL MODEL RSM-1 REMOTE SPEAKER/MIC CONNECTIONS

OPTIONAL RELAY OUTPUT CONNECTIONS

INSTALL TRANSFORMER

CONSOLE

EMERGENCY

DXT-61A

DXS-21

DXS-23

DXT-41

DXT-42

FIRE

ACTIVITY

DXS-31

DXS-72

DXS-31/32

DXS-54

R

A

D

I

O

S

I

G

N

A

L

S

TO CENTRAL STATION

VIA TELEPHONE

DXS-62

DXS-63

EMERGENCY BUTTON

• PRESS AND HOLD TO TRIGGER

THE EMEREGNCY ZONE

POWER INDICATOR

TROUBLE INDICATOR

SENDING INDICATOR

HOME INDICATOR

• LIGHTS WHEN AC IS PRESENT
• BLINKS SLOWLY WHEN BATTERY IS CHARGING
• BLINKS QUICKLY WHEN AC IS ABSENT (CONSOLE ON BATTERY POWER)
• OFF IN TEST AND SETUP MODES

• NORMALLY OFF
• LIGHTS WHEN ANY TRANSMITTERS ARE MISSING (SUPERVISORY)
• BLINKS SLOWLY WHEN ANY TRANSMITTERS HAVE A LOW BATTERY

• NORMALLY OFF
• FLASHES WHEN CONSOLE IS PLACING A CALL

• LIGHTS WHEN ACTIVITY TIMER IS ON
• BLINKS SLOWLY WHEN LESS THAN 15 MINUTES IS LEFT ON THE ACTIVITY TIMER
• BLINKS QUICKLY WHEN THE ACTIVITY TIMER HAS EXPIRED

CLEAR BUTTON

HOME BUTTON

• STOPS ALARM

• ADDS CANCEL TO AN ALARM

REPORT IN PROGRESS

• PRESS IMMEDIATELY AFTER

EMERGENCY TO PREVENT REPORT

• CLEARS INDICATORS

• STOPS TROUBLE BEEPER

• PRESS FOR 5 SECONDS TO ADD

A TRANSMITTER

• PRESS TO RESET ACTIVITY TIMER

• PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF

• IF ACTIVITY TIMER IS OFF, PRESS FOR 

5 SECONDS TO TURN ACTIVITY TIMER ON

HOME BUTTON COVER

• ADHESIVE BACKED PLATE TO

HIDE THE HOME BUTTON IF THE

ACTIVITY TIMER IS NOT USED

TO ACCESS THE INSIDE OF THE CONSOLE
PRESS THE TWO LOCKING TABS IN AND
REMOVE THE CONSOLE'S BOTTOM COVER

PRESS

TABS

IN

REMOVE

COVER

16 VAC 1.25 AMP

PLUG-IN

TRANSFORMER

EXTERNAL SPEAKER
AND RELAY OUTPUT
TERMINALS

VOICE DIALER JACK

LOCAL PHONE SET JACK

TELEPHONE LINE JACK

12-VOLT 1.2 AMP/HOUR

BACKUP BATTERY

BATTERY SWITCH

3 AMP 2AG

BATTERY FUSE

(HIDDEN)

TEST BUTTON

OPTIONAL

VB-4 VOICE BOARD

CONNECT BLACK 

MICROPHONE 

WIRE TO CENTER 

TERMINAL

CONNECT RED 

MICROPHONE WIRE TO 

THIS TERMINAL

1

2

3

4

5

PRESS-FIT MICROPHONE INTO

ROUND MOUNTING HOLE

SEAT

MICROPHONE

CAREFULLY ALIGN

PINS TO CONNECTORS

ON BOTH ENDS OF BOARD

NOTE: POWER MUST

BE OFF AND BATTERY

SHOULD BE REMOVED

OR DISCONNECTED

BEFORE INSTALLING

THE AUDIO BOARD

BE SURE THAT THE WHITE

ARROWS ON AUDIO BOARD

POINT TOWARDS THE

BATTERY AREA

PRESS BOARD COMPLETELY

INTO CONNECTORS

NOTE: AFTER THE AUDIO BOARD
IS INSTALLED AND ENABLED,
THE CONSOLE WILL SPEAK  INSTEAD
OF BEEP DURING PROGRAMMING

1

2

3 - RELAY COMMON

4 - NORMALLY CLOSED

5 - NORMLLY OPEN

FORM C DRY CONTACT RELAY
24 VOLTS AT 1 AMP MAXIMUM

NOISEMAKER OR

VISUAL INDICATOR

EXTERNAL

POWER SUPPLY

PERS-2400 CONSOLE

CONNECT WIRES
TO TERMINALS

ROUTE CABLE UNDER
STRAIN-RELIEF CLAMP

1 - EXTERNAL SPEAKER

2 - EXTERNAL SPEAKER

3

4

5

PERS-2400 CONSOLE

TERMINAL BLOCK

VB-4 TERMINAL BLOCK

EXTERNAL MICROPHONE (+)

MICROPHONE COMMON (-)

CONSOLE MICROPHONE (+)

LINEAR MODEL RSM-1

RSM-1 TERMINAL BLOCK

SPKR

SPKR

MIC (-)

MIC (+)

VB-4
VOICE
BOARD

RSM-1
TERMINALS

USE TWISTED
PAIR WIRE FOR
MICROPHONE

NOTE: REMOVE
JUMPER WHEN

USING AN

EXTERNAL SPKR

REMOVE

JUMPER

WIRE

NOTE: NOT

TESTED BY UL

1

2

TURN BATTERY
SWITCH OFF

OFF

ON

BATTERY TYPE: 12-VOLT, 1.2 AMP/HOUR

CONNECT RED LEAD TO POSITIVE
AND BLACK LEAD TO NEGATIVE
BATTERY TERMINAL

3

FIT BATTERY
INTO CONSOLE

SLIDE DOWN

THEN BACK

LIGHT CONCRETE

OR BRICK

65% - 95%

OF FULL POWER

10% - 70%

OF FULL POWER

CONCRETE WITH STEEL

REINFORCEMENT OR

METAL LATH AND PLASTER

WALLBOARD AND

WOOD STUDS

90% - 100%

OF FULL POWER

CONSTRUCTION

MATERIALS WILL

EFFECT RADIO RANGE

WIRELESS INSTALLATION TIPS

WRONG!

RIGHT

CENTRALLY LOCATE CONSOLE

TRANSMITTERS AT THE OTHER END OF

HOUSE MIGHT BE TOO FAR AWAY

CONSOLE LOCATION WILL

EFFECT RADIO RANGE

OFF

ON

1

PLUG TRANSFORMER
INTO AN UN-SWITCHED
117 VAC OUTLET

2

3

TURN BATTERY
SWITCH ON

SECURE
TRANSFORMER
WITH SCREW

Reviews: