background image

DF-54/EC

MOTION

DETECTOR

For Use with DF-16/EC

Security Console

Installation
Instructions

1.  MOTION DETECTOR DETAIL

2. TYPICAL INSTALLATION

3.  MOTION DETECTION PATTERN

4. CONNECT BATTERY

5.  MOUNT MOTION DETECTOR BASE

6.  PROGRAM DETECTOR INTO CONSOLE

7.  WALK TEST MOTION DETECTOR

8.  ALARM TEST MOTION DETECTOR

9.  REPLACING MOTION DETECTOR BATTERY

10.  IMPORTANT DETECTOR INFORMATION

1.

I

NTERNATIONAL WARRANTY

This Linear product is warranted against defects in material and workmanship for twelve (12) months. 
The Warranty Expiration Date is labeled on the product. 

This warranty extends only to wholesale 

customers

 who buy direct from Linear or through Linear’s normal distribution channels. 

Linear does 

not warrant this product to consumers.

 Consumers should inquire from their selling dealer as to 

the nature of the dealer’s warranty, if any. 

There are no obligations or liabilities on the part of 

Linear Corporation for consequential damages arising out of or in connection with use or 
performance of this product or other indirect damages with respect to loss of property, 
revenue, or profi t, or cost of removal, installation, or reinstallation. 

All implied warranties, 

including implied warranties for merchantability and implied warranties for fi tness, are valid only until 
Warranty Expiration Date as labeled on the product. 

This Linear Corporation Warranty is in lieu of 

all other warranties express or implied.

 For warranty service on Linear equipment return product, 

at sender’s expense to:

Linear Hong Kong 19/F Hounor Industrial Centre, 6 Sun Yip Street Chai Wan, Hong Kong 
Attention: Repairs Department
REPAIRS POLICY
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by 
the effects of lightning, water, fi re, or other abnormal happenings.Customer’s equipment sent in for repair 
may be repaired or replaced with new or remanufactured equipment at Linear’s discretion.The customer 
is always responsible for shipping and handling charges to the repairs facility. Linear will pay return 
shipping and handling charges on “in warranty” products shipped back to the customer. The customer will 
be billed for the return shipping and handling charges on “out of warranty” products.There will be a 50% 
expedite fee for any express requests.The International Sales Manager must be notifi ed prior to the return 
of product to Linear. All international returns must have an International Repair Authorization number 
(IRA#). The number must be marked on all packages. Failure to do so will cause delays in processing.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless 
signaling. However, there are some limitations which must be observed. The radios are required to comply with 
local rules and regulations as radio devices. As such, they have limited transmitter power and therefore limited 
range. A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio 
signals that occur on or near their operating frequencies, regardless of code settings. Changes or modifi cations 
to the device may void regulatory compliance. Infrequently used radio links should be tested regularly to protect 
against undetected interference or fault. A general knowledge of radio and its vagaries should be gained prior to 
acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

(760) 438-7000 • FAX (760) 438-7043

www.linearcorp.com

PRINTER’S INSTR

UCTIONS:

INSTR,INSTL,DF-54/EC - LINEAR P/N:

 210948 B - INK:

 BLA

CK - MA

TERIAL:

 20 LB

. MEAD BOND - SIZE:

 11.000”

 X 8.500”

 - SCALE:

 1-1

WALK
TEST
BUTTON

MOTION
DETECTOR
LENS

CASE
LOCKING
SCREW
(ON BOTTOM)

MOTION

DETECTOR

DON'T POINT AT HEAT SOURCES 
(HEATERS, ETC.), WINDOWS, OTHER 
MOTION DETECTORS OR DOOR/WINDOW
TRANSMITTERS

BEDROOM

BATH

KITCHEN

FRONT
ROOM

CONSOLE

(FOR INDOOR

USE ONLY)

MOUNT

DETECTOR

SO THAT

INTRUDER

WILL CROSS

BEAMS

DETECTION

AREA

9 METERS

9 METERS

9 METERS

2-3 METERS

SIDE

VIEW

TOP

VIEW

MOTION
DETECTOR
IN CORNER

REMOVE
SCREW
AND OPEN
CASE

CONNECT 9-VOLT ALKALINE
BATTERY TO BATTERY CLIP
(PLUS SIDE UP)

NOTE:

WAIT 5 MINUTES AFTER
CONNECTING BATTERY

FOR DETECTOR

TO STABILIZE

PUNCH OUT REQUIRED HOLES
FOR SCREW MOUNTING

USE CENTER

HOLES FOR

WALL

MOUNTING

USE SIDE HOLES

FOR CORNER

MOUNTING

NOTE:

THE DETECTOR CAN
BE MOUNTED WITH
DOUBLE STICK TAPE,

MOUNT
DETECTOR
6-8 FEET
HIGH

MOUNTING THE DETECTOR
IN A CORNER IS PREFERRED

AFTER MOUNTING, SNAP
DETECTOR ONTO BASE
AND REPLACE CASE SCREW

1

ENTER YOUR

SECRET CODE

PRESS
LEARN

ENTER AN

UNUSED SENSOR

NUMBER

PUSH WALK

TEST BUTTON

TO SEND SIGNAL

FROM MOTION

DETECTOR

START IN

OFF MODE

HOLD OFF BUTTON
FOR 3 SECONDS WHEN
FINISHED TO EXIT
LEARN MODE

LEARN BUTTON

WALK
TEST
BUTTON

PUSH
WALK
TEST
BUTTON

WALK IN FRONT OF 
UNIT WHILE WATCHING 
RED LIGHT

UNIT WILL STAY IN
WALK TEST MODE
FOR 4 MINUTES AFTER
PRESSING WALK TEST
BUTTON THEN AUTOMATICALLY
RETURN TO "OPERATE" MODE

VERIFY THAT DETECTION
PATTERN COVERS DESIRED
AREA & THAT CONSOLE
STATUS INDICATOR LIGHTS
WHEN MOTION IS DETECTED

AFTER INITIAL SETUP,
WALK TEST UNIT YEARLY

NOTE:

EMERGENCY

EMERGENCY

PLACE CONSOLE IN OFF MODE
TO STOP SIREN, CHECK THAT SENSOR
STATUS LIGHT IS BLINKING.

AFTER FIVE MINUTES, WALKING
IN FRONT OF THE MOTION DETECTOR
SHOULD TRIGGER THE ALARM

PLACE CONSOLE IN THE
AWAY MODE

STAY OUT OF THE MOTION
DETECTION PATTERN AREA
FOR AT LEAST FIVE MINUTES

REMOVE
SCREW
AND OPEN
CASE

WHEN CONSOLE INDICATES A LOW BATTERY
FOR THIS SENSOR:

REPLACE THE BATTERY WITH
A FRESH 9-VOLT ALKALINE
BATTERY (PLUS SIDE UP)

USE ALKALINE
BATTERY ONLY

SNAP DETECTOR ONTO BASE
AND REPLACE CASE SCREW
WHEN FINISHED

NOTE: WAIT 5 MINUTES AFTER REPLACING
BATTERY FOR DETECTOR TO STABILIZE

1. The motion detector can only trigger the alarm 
when the Console is in Away Mode.
2. Except in “Walk Test”, the detector must see no 
motion for fi ve minutes before walking in front of 
the unit will send an alarm signal.
3. When the Console is in Away Mode, the motion 
detector will cause an instant alarm unless a 
delayed perimeter door/window sensor is triggered 
fi rst.
4. Operating temperature range: 
+32° to +120° F (0° to +49° C)

R&TTE VAEE 27837, EMC, SFT, ETS

Linear Corporation declares that the apparatus 
DF-54/EC complies with the essential requirements 
and other relevant provisions of Directive 1995/5/EC.

Copyright © 2003 Linear Corporation 

210948 B

BY

Reviews: