AM3Plus

Access Controller

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,AM3PLUS - LINEAR P/N: 227542 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH

Installation Instructions

Summary of Contents for AM3Plus

Page 1: ...AM3Plus Access Controller 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation Instructions...

Page 2: ...code number Arriving visitors would use a remote keypad to enter their entry code Also proximity receivers swipe card readers and other remote devices can be used with the system Block coded MegaCode...

Page 3: ...reset time or depending on the cardholder s access direction Feature Overview Relay Outputs Four 3 amp dry contact relay outputs are provided to activate four access devices such as door strikes magne...

Page 4: ...be mounted indoors in a standard single gang electrical box Tamper resistant screws secure the keypad to its mounting plate The die cast keys have bright easy to read yellow graphics and is illuminat...

Page 5: ...TTON ENTER BUTTON STATUS PROGRAM DISPLAY ARROW BUTTONS STATUS INDICATORS RELAY INDICATORS 4 RELAY LATCH BUTTONS 4 AM MIO INTERFACE CONNECTOR HIDDEN POWER SWITCH TERMINAL BLOCKS TELEPHONE LINE CONNECTO...

Page 6: ...LTIPLE NETWORK UNITS REFER TO NETWORK SECTION FOR WIRING OPTIONS NETWORK UNIT UP TO SIX PBUS DEVICES CAN BE USED WITH EACH AM3PLUS UP TO SIX PBUS DEVICES CAN BE USED WITH EACH AM3PLUS FOR LOCAL COMPUT...

Page 7: ...loaded pedestrian gate must be isolated from the keypad NEVER MOUNTTHE KEYPAD DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AM3Plus is used to control a gate operator connected to a vehi...

Page 8: ...and secure it with the two screws provided Outdoor Cabinet To protect the unit outdoors the AM3Plus can be mounted inside a Linear Model CAB 3 P N ACP000913 outdoor metal cabinet Wiring access for pow...

Page 9: ...ly used with push bars loop sensors or pushbuttons 1 Install the pushbutton or device to signal an exit request 2 Route two wires from the device to the AM3Plus 3 Connect the device s normally open ou...

Page 10: ...y is not required to maintain the AM3Plus clock calendar and programming memory during power outages 1 Route two battery leads between the AM3Plus and the backup battery 2 Connect the Battery positive...

Page 11: ...Receiver AM RPR Radio Proximity Receiver AM KP Exterior Keypad AM KPI Interior Keypad AM CRI Card Reader Interface Conventional cable or commonly available Cat 5e Ethernet cable can be used to connect...

Page 12: ...accessory For wire runs up to 300 feet use 24 AWG Belden 9931 or equivalent For wire runs up to 500 feet use 20 AWG Weico 9405 or equivalent 3 Connect the cable to the accessory and the AM3Plus as sho...

Page 13: ...supported AXNET network hardware configurations and associated Network Configuration Numbers After choosing a network layout that best suits the installation note the Network Configuration Number Thi...

Page 14: ...ight networks each with eight nodes for a total of 64 units RS 485 CABLE CONNECTION NETWORK NODE 1 ALWAYS REQUIRES A MODEM FOR REMOTE PROGRAMMING MODEM UNIT NETWORK NODE FULL ACCESSBASE2000 NETWORK NO...

Page 15: ...other units Repeat this step to connect the hub unit to each of the other units 4 Connect the 3 conductor cable to each unit s NETWORK terminals Network Daisy chain Wiring 1 Mount and install the uni...

Page 16: ...y Table 4 When the desired option is displayed press the ENTER button to select the option NOTE In network installations a unique network address 1 8 for AccessBase2000 1 4 for AXNET must be set befor...

Page 17: ...a credential is validated and access is granted PBUS blinks when any PBUS device is successively decoded READER A flashes when Wiegand A device is successively decoded READER B flashes when Wiegand B...

Page 18: ...ystem will not answer an incoming call 1 Automatic telephone answer disabled 2 AM3Plus telephone line trouble 3 ACM 1 Modem not installed or not installed correctly check that all the modem pins are c...

Page 19: ...at 1 800 421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user s authority to o...

Page 20: ...Copyright 2007 Linear LLC 227542 A...