DEMO MANUAL DC1453A

V

IN

+

+

+

0A ~ 4A

+

+

LOAD

0A ~ 4A

+

+

LOAD

QUICK START PROCEDURE

Demonstration circuit 1453A is an easy way to evaluate the 
LTM4619. If V

IN

 is always below 5.5V, stuff a 0Ω resistor 

at R16. Do not stuff R16 if V

IN

 is higher than 5.5V. Please 

refer to Figure 1 for proper measurement equipment setup 
and follow the procedure below:

1. Place jumpers in the following positions for a typical 

3.3V and 1.8V application:

MODE/

CLK SEL.

RUN1

FREQUENCY

TRACK1

RUN2

TRACK2

CCM

On

500kHz

Soft-Start

On

Soft-Start

2. With power off, preset the loads to 0A and V

IN

 supply 

to be less than 28V. Connect the input power supply, 
load and meters as shown in Figure 1.

3. Turn on the power at the input. The output voltage 

between V

O1

+

 and V

O1

 should be 3.3V ±2%, and the 

voltage between V

O2

+

 and V

O2

 should be 1.8V ±2%.

4. Once the proper output voltage is established, adjust 

the load within the operating range and observe the 
output voltage regulation, ripple voltage, effi ciency and 
other parameters.

  To measure input and output ripple, please refer to Fig-

ure 2 for proper setup. Keep in mind at high switching 
frequencies and/or high input voltages, lower output 
voltage may not regulate properly due to the minimum 
on time of the regulator. Refer to the data sheet for more 
details.

5. For output voltage tracking during start-up and shut-

down, set jumpers JP3 and JP4 to EXT SIGNAL and 
apply a valid voltage signal to E8 and E10.

6. To synchronize the switching frequency to an external 

clock set jumper JP2 in the EXT. CLK position and the 
jumper JP1 in the BURST MODE / EXT. CLK position. 
Apply a valid clock signal on the CLK SYNC test point.

Figure 1. Test Setup of DC1453A

Figure 2. Proper Scope Probe Placement 
for Measuring Input or Output Ripple

INPUT OR OUTPUT CAPACITOR

Reviews: