Linear Technology 1158A Quick Start Manual Download Page 1

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1158A 

MONOLITHIC SYNCHRONOUS BUCK REGULATOR 

 

 

1

 

 

 LTC3564 

DESCRIPTION  

Demonstration circuit DC1158A is a high efficiency 
monolithic  synchronous  buck  regulator  using  a 
constant frequency, current mode architecture fea-
turing  LTC3564.  Its  high  switching  frequency  of 
2.25MHz  allows  the  use  of  small  surface  mount 
inductors  and  capacitors.  Supply  current  during 
operation  is  only  20uA  dropping  to  below  1uA  in 
shutdown.    The  2.5V  to  5.5V  input  voltage  range 

makes the LTC3564 ideally suited for single Li-Ion 
battery-powered or 3.3V to 5V input voltage appli-
cations.  100%  duty  cycle  provides  low  dropout 
operation,  extending  battery  life  in  portable  sys-
tems. Automatic Burst Mode® operation increases 
efficiency  at  light  loads,  further  extending  battery 
runtime. 

Gerber  files  for  this  circuit  are  avail-

able. 

Call 

the 

LTC 

Factory.

 

Table 1. 

Performance Summary (T

A

 = 25ºC) 

PARAMETER 

CONDITION 

VALUE 

Input Voltage 

 

2.5V to 5.5V 

Output Voltage V

OUT

 

I

OUT

=0A to 1.25A 

V

OUT

 ± 0.5% 

Maximum Output Current 

 

1.25A 

DC Supply Current 

V

FB

 = 0.5V or V

OUT

 = 90%, I

OUT

 = 0A 

300

µ

Nominal Switching Frequency 

V

FB

 = 0.6V or V

OUT

 = 100% 

2.25MHz 

 

QUICK START PROCEDURE

 

The DC1158A is easy to set up to evaluate the 
performance  of  the  LTC3564.  For  a  proper 
measurement  equipment  configuration,  set  up 
the circuit according to the diagram in Figure 2. 

NOTE:  When  measuring  the  input  or  output  volt-
age  ripple,  care  must  be  taken  to  avoid  a  long 
ground  lead  on  the  oscilloscope  probe.  Measure 
the  input  or  output  voltage  ripple  by  touching  the 
probe tip directly across the V

IN

 or V

OUT

 and GND 

terminals.  See  the  Measurement  Equipment  Set-
up  diagram  in  Figure  1  for  proper  scope  probe 
technique. 

Please  follow  the  procedure  outlined  below  for 
proper operation. 

1.  Connect  the  input  power  supply  to  the  V

IN

 

and GND terminals. Connect the load between 

the V

OUT

 and GND terminals. Refer to Figure 2 

for the proper measurement equipment setup. 

2.  Before  proceeding  to  operation,  insert 
jumper  shunt  XJP1  into  the  OFF  position  and 
insert  jumper  shunt  into  XJP2,  XJP3  or  XJP4 
for  voltages  of  1.2V,  1.5V  or  1.8V  respectively. 
Set  the  load  output  current  to  less  than  1.25A. 
An optional output voltage can be set by popu-
lating resistor RFB6, removing RFB5 and mov-
ing the shunt jumper to JP5. 

3.  Apply  5V  at  V

IN

.  Measure  V

OUT

;  it  should 

read  0V.    If  desired,  one  can  measure  the  shut-
down supply current at this point.  The supply cur-
rent will be about 1 µA in shutdown.  

4.  Turn on V

OUT

 by changing shunt XJP1 from 

the  OFF  position  to  the  ON  position.   The  out-
put  voltage  should  measure  according  to  the 

Reviews: