P/N 1604010 Rev D (ECN 35207)
3-1
Multi-Control Operation Manual
Section 3 - Service
Section 3 - Service
System Alerts
All service should be performed by a Lindsay Dealer. For equipment issues or issues with the FieldNET portal /
mobile application, please contact the FieldNET support team at 866.MY.FIELD (866-693-4353) in the USA, or
email support at [email protected].
Alert
Default Level
Cause
High System Flow Shutdown
1- High
Shutdown due to system flow exceeding the allow-
able limit.
Low System Flow Shutdown
1- High
Shutdown due to system flow being lower than the
allowable limit.
High Flow Disparity Shutdown
1- High
Shutdown due to flow disparity exceeding the allow-
able variation limit when flow is high.
Low Flow Disparity Shutdown
1- High
Shutdown due to flow disparity exceeding the allow-
able variation limit when flow is low.
High System Pressure Shutdown
1- High
Shutdown due to system pressure exceeding the
allowable limit.
Low System Pressure Shutdown
1- High
Shutdown due to system pressure being lower than
the allowable limit.
High Temperature Shutdown
1- High
Shutdown due to system temperature exceeding
the allowable limit.
Low Temperature Shutdown
1- High
Shutdown due to system temperature being lower
than the allowable limit.
High Injector Flow Shutdown
1- High
Shutdown due to flow through an injector exceeding
the allowable limit.
Low Injector Flow Shutdown
1- High
Shutdown due to flow through an injector being
lower than the allowable limit.
High Voltage Shutdown
1- High
Shutdown due to system voltage exceeding system
capacity.
Low Voltage Shutdown
1- High
Shutdown due to system voltage being too low for
system capacity.
Wireless Switch Battery Shutdown
1- High
A wireless switch has caused a shutdown due to a
problem with the battery.
Wireless Switch Solar Panel Error
1- High
A wireless switch has caused a shutdown due to a
problem with the solar panel.
Wireless Switch Communication Error 1- High
A wireless switch has failed to communicate with
the system after multiple attempts to contact it.
Powered Off While Running Wet
1- High
The Multi-Control lost power or turned off while the
system was irrigating.
High Rainfall Shutdown
1- High
Shutdown due to rainfall accumulation in the rain
bucket exceeds the programmed limit.
High pH Shutdown
1- High
High pH amounts detected in the water exceed the
expected limits.
Low pH Shutdown
1- High
pH amounts in the water are lower than the lowest
programmed limit.
Hardware Shutdown
1- High
A component failure has caused the shutdown.
Summary of Contents for GrowSmart Multi-Control
Page 1: ...Multi Control Operation Manual P N 1604010 Rev D ECN 35207...
Page 2: ......
Page 10: ...P N 1604010 Rev D ECN 35207 Multi Control Operation Manual Table of Contents...
Page 22: ...P N 1604010 Rev D ECN 35207 2 4 Multi Control Operation Manual Section 2 Operation...
Page 26: ...P N 1604010 Rev D ECN 35207 3 4 Multi Control Operation Manual Section 3 Service...
Page 28: ...P N 1604010 Multi Control Operation Manual Revisions...