The welding arc is “cold.” The
welding arc is not stable or is not
satisfactory. the engine runs nor-
mally. The auxiliary power is nor-
mal.
1. Make sure the MODE selector
switch is in the correct position
for the process being used. (For
example, CV-WIRE, PIPE, CC-
STICK.)
2. Make sure the electrode (wire,
gas, voltage, current etc.) is cor-
rect for the process being used.
3. Check for loose or faulty con-
nections at the weld output ter-
minals and welding cable con-
nections.
4. The welding cables may be too
long or coiled, causing an exces-
sive voltage drop.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.