Page 1: ...ctions 2 2A 10001 G07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Quicklub Progressive Metering Devices for Grease and Oil Model SSV and SSV M Planning and Layout o...

Page 2: ...6227 33 0 Fax 49 6227 33 259 All rights reserved Any duplication of this User Manual in its entirety or in part by whatever means is prohibited without the prior consent in writing of Lincoln GmbH Su...

Page 3: ...ependent monitoring 15 Visual monitoring 15 Electrical monitoring microprocessor control 16 Pressure relief valve 16 Determining the Lubricant Output by Combining Outlets 17 Tube Fittings Screw Type 1...

Page 4: ...or sequence of contents Procedural instruction User s Responsibility To ensure the safe operation of the unit the user is responsi ble for the following 1 The pump system shall be operated only for t...

Page 5: ...is to be used 1013A94 CAUTION Danger of injury in the case of serious corrosion of metering device surfaces An increasing corrosion of the surfaces will cause the balls pressed in to lose their hold U...

Page 6: ...ferrule 3 valve body with seal and clamp ring Tube Fittings Push in Type 1008a98 Fig 2 Inlet fittings 1009a98 Fig 3 The different types of check valve Metering Devices Inlet tube fittings straight and...

Page 7: ...e inlet fittings towards the lubrication point knurled collet 6001a02 NOTE Exceptionally the high pressure hose 4 1 x 2 3 mm with threaded sleeve and hose stud may also be used for the low pressure se...

Page 8: ...echnical Data when installing the parts Installing the threaded sleeves and hose studs on the high pressure hose Screw the threaded sleeve item 1 Fig 30 counter clock wise onto the high pressure plast...

Page 9: ...fer the option of combining several lubrication points into one centralized lubrication point meter the supplied lubricant into predetermined single quantities can be monitored visually SSV and SSV M...

Page 10: ...valves SSV M and SSV operate in the same way Apart from their outer dimensions see be low dimensions they also differ in the following data also see fig 11 SSV Lubricant output per outlet and per stro...

Page 11: ...ne to one or more central lubrication points as shown in Fig 12 which illustrates this basic feature 4024b95 Fig 13 Possible pump connections When they are used in connection with hand operated pumps...

Page 12: ...ystem expanded by a progressive metering device Progressive metering devices can be used in two line or single line centralized lubrication systems in order to in crease the number of outlets of multi...

Page 13: ...tions are derived from the logical pumping sequence 2007a99 Fig 17 Phase 1 Phase 1 The lubricant enters the metering device from above white arrow and flows to the right hand end of piston A Piston A...

Page 14: ...4 The channel to the right hand end of piston D is now open black arrow The lubricant which is fed from above white arrow moves piston D to the left causing the lubricant quantity ahead of the left h...

Page 15: ...tream of the pump stops op erating The fundamental internal structure of the progressive metering device guarantees the self monitoring of the se quence within the metering device The linkage makes it...

Page 16: ...mitted to the control unit A fault signal occurs 6001a02 NOTE For the system monitoring it is recom mended that one SSV metering device with pre assembled piston detector be used per lubrication circu...

Page 17: ...utlet fitting assembly 5 M 10x1 in each outlet borehole which will be used Refer to Fig 26 27 28 Never remove closure plug 4 M 11x1 chamfered on the piston side or remove it only for installing a pist...

Page 18: ...sage 1 Inlet fitting optionally with protective cap 1 3 Closure plug with copper washer installed in outlet borehole 6 Junction channels 2 Delivery borehole of the piston 4 Closure plug M 11x1 piston...

Page 19: ...for pos 3 1014b96 Fig 29 Single double and triple lubricant output x Outlet quantity 1x single 2x double etc 1 10 Outlet numbers A Clamping ring brass Single lubricant output The simple lubricant outp...

Page 20: ...voltage of the drive motor Select the printed circuit board or timer in accordance with the application Note the application possibilities for the metering device monitoring Protect the pump with an...

Page 21: ...ating the metering devices 5 Allocating a metering device with the appropriate number of outlets to each group It is recommended that metering devices with 6 8 10 or 12 outlets be used in special case...

Page 22: ...larger lubricant quantities See direct connection of the metering device to respectively one single pump element example Fig 37 If necessary modify the allocation of the lubrication points Maximum si...

Page 23: ...3 and 205 at 100 bar backpressure at 20 C at 24 V rated voltage Pump element K5 2 cm3 min 0 10 cm stroke Pump element K6 2 8 cm3 min 0 15 cm stroke Pump element K7 4 cm3 min 0 22 cm stroke Adjustable...

Page 24: ...ingle Double Secondary metering device SSV 6 3 min 4 min 5 min 6 min SSV 8 4 min 5 5 min 6 5 min 8 min SSV 10 5 min 2 5 min 6 5 min 3 5 min 8 5 min 4 5 min 10 min 5 min SSV 12 6 min 3 min 8 min 4 min...

Page 25: ...nuation Instructions for Quicklub Progressive Systems continuation 4022b95 11 Connecting machine bearings Fig 40 Example of connection for machine bearings 1018a96 12 Connecting a fifth wheel Fifth wh...

Page 26: ...s superstructure or auxiliary unit can be supplied from a specially installed pump element 6001a02 IMPORTANT Each pump element must be equipped with a pressure relief valve 1022a96 Fig 44 Using a quic...

Page 27: ...ade only via 2 steps of metering devices i e main metering device secondary metering device lubrication point 1023b96 A Main metering device B Secondary metering device Fig 45 Maximum line lengths C L...

Page 28: ...8 bar m 6 bar m Maximum pressure loss through each SSV 6 to SSV 12 NLGI 0 20 bar 15 bar 10 bar NLGI 1 25 bar 20 bar 15 bar NLGI 2 30 bar 25 bar 20 bar 6001a02 NOTE The data relating to the pressure lo...

Page 29: ...alled on the metering devices if any no longer move c the fault signal of the signal lamp if any or LED display 6001a02 NOTE If there is a blockage in the downstream system the main lines are under pr...

Page 30: ...using a pin Clean the metering devices again and blow them through Reassemble the metering devices Replace the copper washers Before the tube fittings are reassembled the metering devices should be p...

Page 31: ...Type and Push inType Tube Fittings High pressure range p max 350 bar Inlet tube fittings of the metering devices Outlet fittings main metering device Low pressure range p max 250 bar Outlet fittings s...

Page 32: ...chnical Data continuation Dimensions Metering Devices Model SSV 6 to SSV 22 2012a95 Fig 48 Metering Devices Model SSV 6 to SSV 22 Model SSV Dimensions A in mm 6 60 8 75 10 90 12 105 14 120 16 135 18 1...

Page 33: ...raphite that are transportable in lubrication systems only conditionally The lubricants released by us have not been tested with re gard to their long term behavior 6001a02 IMPORTANT The manufacturer...

Page 34: ...2 EP Li 20 C DEA Glissando 20 Li 12 OH stearat 15 to 10 C ESSO Ronex Extra Duty 2 Li complex 5 C ESSO Ronex MP2 Li complex 5 C ESSO Beacon EP2 Li 5 C ESSO Cazar K2 Ca 15 C FIAT LUBRIFICANTI Comar 2 Li...

Page 35: ...Manufacturer Designation Thickener min delivery temperature ARAL EURAL Grease EPF 2 Al complex 5 C BREMER LEGUIL Rivolta F L G 4 2 Al complex 20 C ELKALUB GLS 364 organic thickener 10 C ELKALUB GLS 36...

Page 36: ...One Lincoln Way St Louis MO 63120 1578 USA Phone 1 314 679 4200 Fax 1 800 424 5359 Lincoln GmbH Heinrich Hertz Stra e 2 8 69190 Walldorf Germany Tel 49 6227 33 0 Fax 49 6227 33 259 Lincoln Industrial...