Lincoln Quicklub System Operation 

and Troubleshooting Guide 

 
 
 

System Operation 

 
The key components of the Quicklub system are: 
1. 

Pump

 with integrated system control and monitoring 

2.  Proximity Switch 

3.  Divider valve network consisting of a 

Primary Valve

 and 

Secondary Valves

 

 
4.  A lubrication event is initiated by actuating the pump via the integrated controller based 

on a preset “pause time” or time between lubrication events.  

 
5.  The 

Pump

 dispenses lubricant to the primary divider valve 

 
6.  The 

Primary Valve

 distributes the lubricant to the secondary valves 

 
7.  The 

Secondary Valves

 distribute and dispense lubricant to the lubrication points. 

 
8.  Lubricant flow through the divider valves actuates the 

Proximity Switch

, which sends a 

signal back to the integrated controller/monitor acknowledging proper system operation 
and turning off the pump. 

 
9.  The controller now begins countdown for the next lubrication event. 
 