A-4
INSTALLATION
CV-525
A-4
Installation of Equipment Required for
Recommended Processes
Note:
Only one wire feeder should be connected to the
CV-525 power source. If two or more are connected to
the CV-525 power source it will not work properly.
WIRE FEEDER CONTROL CABLE CONNECTIONS
For control cable with WF-L(14-pin) connector:
Connect control cable to WF-L connector on the front
panel of the machine labeled WF-L. See the appropri-
ate connection diagram for the exact instructions for
the wire feeder being used. Refer to
“
115VAC and
42VAC Auxiliary Power and Control Connections
”
section for connector pin functions.
A cover (Lincoln Electric Part Number S17062-3) is
available for the unused WF-L connector to protect it
against dirt and moisture.
CONNECTION OF CV-525 TO LN-22 OR LN-25
a) Turn off all power.
b) Connect a jumper between pins
“
C to D
”
in WF-L
connector plug, (a K484 14-pin jumper plug is
available).
c) Connect the electrode cable to the output terminal
of polarity required by electrode. Connect the work
lead to the other terminal.
d) Place the OUTPUT CONTROL Switch at
“
LOCAL
”
position unless a Remote Control is connected to
the CV-525.
NOTE: The output terminals are energized at all
times.
The Feeder Ready LED will stay off when a wire feed-
er is connected to the WF-L connector.
CONNECTION OF CV-525 TO ARCWELD AWF
FEEDERS, OR PANASONIC STYLE / OTC STYLE
WIRE FEEDERS.
a) Turn off all power.
b) Connect the ARCWELD AWF or Panasonic Style
wire feeder to WF-AWF/P receptacle. Connect
OTC style wire feeder to WF-O receptacle.
c) Place the output control switch to the
“
REMOTE
”
position.
d) Turn on the input power. The Feeder Ready LED
should lit up if one of the wire feeders listed in
step (b) is connected correctly to the CV-525.