![Lincoln Electric Statiflex 800 Operator'S Manual Download Page 20](http://html1.mh-extra.com/html/lincoln-electric/statiflex-800/statiflex-800_operators-manual_1918353020.webp)
B-3
OPERATION
STATIFLEX
®
800
INTENDED
USE
Worker exposure level should be checked
upon installation and periodically
thereafter to be certain it is within
applicable federal, state and/or local
regulations and guidelines (i.e. OSHA PEL and ACGIH
TLV limits in the U.S.).
The Statiflex 800 is intended to be used with Lincoln Electric
extraction arm(s) and fan(s). For information on use of these
products, refer to the instruction manuals of the corresponding
arm and/or fan.
FILTER MAINTENANCE INDICATOR
The Statiflex 800 is provided with a Filter Maintenance Indicator
(See Figure B.1). When using the filter unit, regularly check the
Filter Maintenance Indicator when the fan is running. The indicator
slowly moves from green to red as filter cartridge becomes
saturated or clogged.
When the Filter Maintenance Indicator is red, replace the
LongLife
®
filter cartridge. See Filter Replacement for description.
The Filter Maintenance Indicator only
functions when the fan(s) is/are in operation
and the system is properly configured.
Saturation or clogging of the filter
cartridge results in a decrease of the
extraction capacity which could result in a
higher localized concentration of welding
fumes.
When the Filter Maintenance Indicator is entirely red while one fan
is in operation, replace the LongLife filter cartridge. Filter
replacement is described in Maintenance Section.
WARNING
ATTENTION
WARNING
GREEN ZONE
YELLOW ZONE
RED ZONE
0
2
4
6
8
FIGURE B.1
0
2
6
8
CLEANING
ALARM
START/STOP:
MANUAL CLEANING
CLEAR: ALARM
FIGURE B.
2
Manual Clean Button
Alarm Lamp