F-62
F-62
TROUBLESHOOTING & REPAIR
SQUARE WAVE TIG 355
CH1
0 volts
2 ms
20 volts
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....2 ms/Div.
Coupling ............................DC
Trigger .........................Internal
MACHINE LOADED TO 350 AMPS
AT 34VDC
This is a typical DC (+) output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division rep-
resents 2 milliseconds in time. The
machine was loaded with a resis-
tance grid bank. The TIG 355 display
read 350 amps at 34 VDC.
Note: Scope probes connected at
machine output terminals: (+) probe
to electrode terminal, (-) probe to
work terminal.
TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED
DC TIG MODE
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.