ElEcTrical DiaGramS
G-2
iDEalarc® Dc-1500
WiriNG DiaGram - cOmplETE machiNE - (l6427)
K4
C2
SCR5
31A
S
SCR1
S
S
247
DC1500 AMP IDEALARC - WIRING DIAGRAM
4
1
H T
H T
T4
4
2
C
H T
3
3
CONTROL
POWER
TRANS.
H T
B
3
2
H T
207-X
2
1
3
K3
C3
.15MFD
201
F
PRIMARY
THERMOSTAT
L1
H2
L
2
X
1
4
3
208-X
2
32-X
32
211
216
SNUBBER
P.C. BD.
#2
201
NO
1CR
2
2
4
3
6
7
8
9
243
10
11
74
K
GND
241
240
2
3
2
4
3
5
205-X
206-X
1
206
1
205
H T
3
204
256
H T
2
1
H T
2
2
H T
2
T3
215
214
5
232
7
9
8
2
FIRING
CIRCUIT
P.C. BD.
10
11
S
S
A
222
226
32
246
6
2CR
NC
232
204
INPUT
POWER
SW1
T1
1
FAN MOTORS
SCR
THERMOSTAT
229
16 AMP
210
G3
209
.15MFD
31A
STOP
T6
F
31A
215
G2
1
.15MFD
201
5CR
2
1
2
BAFFLE
A.N.S.I. ELECTRICAL SYMBOLS PER E1537.
PROTECTIVE BONDING CIRCUIT
N.C.
A
CENTER TERMINAL
OF FUSE HOLDER
A
239
K1
G6
CONTROL
P.C. BD.
3
4
5
6
6CR
F
OUTPUT
PILOT
RELAY
214
216
215
255
205
203
201-X
204-X
203-X
S
TS1
208
207
73
238
210
210
4
K5
L
3
TO
SUPPLY
LINES
A
C
L
1
B
.15MFD
211
SCR3
4
START
S
2
6
INTERPHASE
REACTOR
L2
F2
AUX. POWER
TRANSFORMER
8
9
1
H T
1
TS6
C6
266
SCR4
CENTER
TERMINAL
OF FUSE
A
1
N.B.
A
212
RECONNECT
PANEL
A
H3
H1
INTERLOCKING
RELAY
A
F
MAIN POWER
TRANSFORMER
T5
6
9
F
1
T2
1
2
3
H T
H T
77
76
75
4
G3
205
206
H3
H2
C
H1
A
7
1
3
6
6
7
8
9
32
31
233
2
TS5
G1
C1
CURRENT
ACTIVATED
REED SW.
K2
4CR
256
242
3
SNUBBER
P.C. BD.
#1
216
FRONT
R
ELECTRODE
POLARITY
F1
W
8A SLOW
BLOW
FUSE
248
253
30
300W
239
D1
R1
246
G2
215
229
32
31
224
230
75
10K
POT
238
237
SW2
SW4
21
SHUNT
(+)
(-)
CONTROL
POWER
TRANS.
32
N.B
.
204
206
208
207
256
214
T7
M
CONTROL
TRANSFORMER
M
255
201
203
SW5
266
WELDING
MODE
N.B.
A
236
74
OUTPUT
CONTROL
TS5
73
226
211
C5
213
234
K
3
215
B
CONTROL
POWER
TRANS.
2
224
234
255
233
235
75
231
226
230
220
1
12
5
4
SCR6
245
235
1
244
2
209
5
211
8
11
INPUT
CONTACTOR
5A FAST
BLOW
FUSE
7
252
4
F
10
F
S
31A
F
32
12
PRECEDING SERIAL No. U1970201000.
32 WAS 202
THE FOLLOWING LEAD NUMBERS WERE CHANGED:
CONNECTED FOR 460V. CONNECTIONS FOR OTHER
06/02/2005
INPUT VOLTAGES MAY BE DIFFERENT. SEE INPUT
31A WAS 31
PRECEDING SERIAL No. U1970201000. ALSO,
NOTE:
N.C. CONNECTION OF F1 AND PILOT LIGHT FOR MACHINES
N.A. TRANSFORMERS T1, T2, T3 AND T4 ARE SHOWN
+
266
G1
12
G4
G5
G6
208
207
G5
K6
250
.15MFD
C4
.15MFD
2
231
SCR2
1
203
CASE
BASE
FAN
N.B. THESE ITEMS ARE NOT INCLUDED IN MACHINES
230
F1
8A SLOW
BLOW
FUSE
202
TS1
32
31A
233
235
249
R2
222
254
G4
COM
FAULT
PROTECTION
RELAY
A
160J
320V
160J
320V
C7
05MFD
05MFD
L642
7PRINT
D
G-2
NOTE:
This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.