5 Seconds
Hold Select button for 5 seconds to enter Menu “GTAW.”
Description
Amplitude of initial starting pulse
Time of initial arc start pulse (1 cycle)
How fast operating current is reached
Minimum current machine will output
Choose whether the starting polarity is negative or positive.
TIG Settings
Display
Item
Choices
AUTO
020
040
1/16
3/32 (Default)
1/8
5/32
ADV
SCRT
Starting Current
2-200 Amps
STME
Starting Time
1-100 ms
SSLP
Starting Slope
0-250 ms
PCRT
Preset Current Minimum
2-25 Amps
EN
EP
Soft Square
Sine
(Default)
Square
Triangular
ON
OFF
ON
OFF
ON
OFF
SPOT
Spot Timer
OFF - 100 s
POL
Starting Polarity
Advanced Trigger
2RST
BILV
4RST
TIG Settings
Setup Menu "GTAW"
DIA
Tungsten Diameter
Waveform Shape
WAVE
The following settings are only available if DIA is set to ADV
Specify your tungsten size for better arc initiation. AUTO
(Intellistart
TM
) automatically manages arc starting conditions to
match adjusted amperage setting. Selecting ADV will allow
manual adjustment of starting parameters.
- Increased puddle control.
Choose which waveform you would like to use.
= Soft sounding arc.
- Faster travel speeds.
- Reduce heat input for thinner materials. Also provides for better
cleaning for anodized applications.
Switch ON to enable 2 Step trigger with restart. See Appendix
for more information.
Switch ON to enable 4 Step trigger with restart. See Appendix
for more information.
Switch ON to enable Bi-level trigger. See Appendix for more
information.
Specify your spot weld time. Default = OFF.