![Linak TECHLINE LA33 User Manual Download Page 32](http://html1.mh-extra.com/html/linak/techline-la33/techline-la33_user-manual_1916970032.webp)
Page 32 of 76
Actuator with proportional control
Connection diagram:
Fig. 11 : 33xxxxxxxxxx3xxx=xxxxxx34/5xxxx
Please be aware that if the power supply is not properly connected, you might damage the actuator!
PWM
BLACK
RED
PROPORTIONAL
BROWN
BLUE
12/24V DC
WHITE
VIOLET
FEEDBACK
SIGNAL GND
Hall
0-10V
PWM
4-20mA
50%
50%
YELLOW
GREEN
IN
OUT
OR
4-20mA
BLACK
RED
PROPORTIONAL
Summary of Contents for TECHLINE LA33