- orient the level transmitter towards the lowest vessel point to ensure level mea-
surement over the entire vessel depth;
- in hot climates, use a visor or canopy to protect the device from direct sunlight;
Fig. 4.3. Installation of device with a visor
- the temperature at the location of level transmitter installation shall not exceed
+50 °C;
If the device is used in a tank, when it is impossible to stick to installation require-
ments for the absence of structures and the flow of incoming product in the measur-
ing beam, observe the following recommendations:
- choose the distance from the vessel wall to the central axis of the level transmitter
within 1/2...1/3 of the tank radius, Fig. 4.4;
NOTE
17
RE_ULM3DX_18_02_20