background image

CLINICIAN INSTRUCTIONS

Summary of Contents for INFINITE SOCKET TT-S

Page 1: ...CLINICIAN INSTRUCTIONS ...

Page 2: ...ts About the Infinite Socket TT S Legend Donning the Socket Closure System Engagement Doffing the Socket Torque Specifications Troubleshooting Warranty Information Technical Appendices 3 5 6 7 8 9 10 11 12 2 ...

Page 3: ...Welcome The following will guide you through basic setup of the Infinite Socket TT S For additional support please call 1 833 233 7249 or visit our Tech Tip videos on youtube com LIMInnovations 3 ...

Page 4: ...ormance or aesthetics providing new levels of force transitions that dynamically conform with the patient s every stride The Infinite socket TT S is designed to accommodate daily volume management The goal is to provide the user an optimal starting point to be able to go about their day using the adjustments provided by the socket Introduction 4 ...

Page 5: ...hanism Note Tools Needed Heat Gun 2 5mm Hex Wrench 4mm Hex Wrench Cover Attachment Posterior Pad Peninsula BOA Fit System optimized by Click Medical 5 Anterior Guide L Bracket Posterior Firmwear proximal Posterior Firmwear distal Pressure Management Strap ...

Page 6: ...Loosen the closure system pull BOA dial away from the socket until an audible click is heard Pull back the posterior firmwear to open Have your patient don the socket Donning The Socket 6 ...

Page 7: ... the BOA dial towards the limb unitil a click can be heard Turn the dial clockwise to achieve desired fit Photo courtesy of Click Medical 7 Tip If patient is experiencing excessive distal end contact check the BOA cable closure system to ensure appropriate fit ...

Page 8: ...Before doffing loosen closure system by pulling the BOA dial away from the limb Disengage suspension mechanism Remove limb from socket Doffing The Socket Infinite Socket TT S Posterior View 8 ...

Page 9: ...Torque Specifications All screws take medium strength threadlocker Loctite 242 8 Hand tight flush with surface Do not over use thread locker and it may damage suspension 3 Nm 3 Nm 10 Nm 9 ...

Page 10: ...u would in a traditional socket Patient having fibular head pressure Turn BOA dial clockwise Make sure alignment is correct Move anterior guides to offload sensitive areas Shift posterior pressure pad laterally Heat remold to increase relief Add socks or padding as you would in a traditional socket Posterior tissue pinching or localized posterior pressure Adjust posterior pad size Adjust posterior...

Page 11: ...cialist who has inspected the product Unapproved modifications or adjustments made by clinicians who are not LIM Clinically Trained Prosthetists are cause for voiding warranty LIM Innovations will either repair or replace damaged parts under warranty at no cost based on an assessment of the problem All replacement sockets parts including any reworks will be covered under a manufacturer s warranty ...

Page 12: ...Appendices Aligning the L Bracket Textile Cover Pressure Management Strap Anteror Guides Anteror Guide Angle Posterior Pad Posterior Wall Height Adjustment Heat Remolding Suspension 13 14 15 17 18 19 20 21 22 12 ...

Page 13: ...acket slides to accommodate up to 26 mm It may be used for foot clearance or alignment needs To adjust 1 Loosen 4 distal mount screws 2 Slide desired amount 3 Tighten 4 distal screws per torque specifications Distal View L Bracket 13 ...

Page 14: ...be removed prior to any adjustments To adjust Remove the cover using a 2 5 mm wrench unscrew from the proximal attachment points and slide away from the socket 14 Tip Cover can be machine washed on cold and left to air dry Infinite Socket TT S Medial view Attachment point highlighted ...

Page 15: ... strap To adjust 1 Release BOA dial to relieve tension in the lace 2 Release strap from peninsula proximal screw and pull to adjust 3 Place screw at desired position 15 Tip It is recommended to allow patient to walk on socket for two weeks before trimming pressure strap excess Infinite Socket TT S Medial view Attachment point highlighted ...

Page 16: ...ed at the level of the patellar 16 Tip It is recommended to allow the patient to walk on the socket for two weeks before trimming pressure strap excess Lateral Adjustments Medial Adjustments When strap is moved to a more medial position the closure system provides a distal bias concentrated at the level of medial tibial plateau ...

Page 17: ... guides using 2 5 mm hex wrench 2 Remove stickers covering additional hole locations 3 Place guide in desired location 17 Tip Anterior guide location change is only available for limbs longer than 15 cm The two most proximal anterior guides cannot be changed in location Infinite Socket TT S Anterior view Attachment point highlighted ...

Page 18: ...ositioned in an orientation that evenly splits the angle of pull Be sure the lace is not running over the screw Loosen and turn the guides according to the diagrams 18 Anterior guide Incorrect line of pull Anterior guide Correct line of pull ...

Page 19: ... the two most proximal anterior guides 2 Slide the anterior elastic up and over the socket 3 Turn the pocket all the way up to expose the pad opening 4 Remove pad and adjust as needed 5 Replace posterior firmwear and tighten screws per torque specs 19 Tip The pad can be replaced using any material and durometer of choice Infinite Socket TT S Posterior view Posterior pocket highlighted ...

Page 20: ... tension from lace 2 Remove screws from the peninsula and reattach at desired position 3 Lowering the posterior wall must be accompanied with the following 20 Tip Ensure both screws are secured when reinstalling Infinite Socket TT S Posterior view Peninsula screws highlighted Anterior guides must be placed at lowest position Posterior trimline of opening must be lowered by 1 cm ...

Page 21: ...s away 3 Heat for approximately 4 minutes while constantly moving the heat gun 4 The socket becomes malleable enough for remolding 5 Avoid distorting the plastic washer in the heating process 6 Allow for cooling before reassembly 21 Tip For spot remolding use a tool to shape the socket Posteriorly the socket is not heat remoldable at the level of the peninsula Any smoke or bubbling indicates you a...

Page 22: ...e green ring is not on the threaded side of the plunger pin 22 Tip If the noise is unresolvable call Bulldog Tools directly at 877 962 0205 Try washers from smallest to largest Pin Lock Adjustments Suction Valve Adjustments 1 If you experience a lack of suction be sure the valve is orientated correctly 2 The valve should be properly orientated with the groove facing down and the gasket between the...

Page 23: ...424 9th Street San Francisco CA 94103 844 888 8546 info liminnovations com www LIMinnovations com ...