Before lifting, keep the following points in mind:

•   A responsible person within your organization should decide on a case-by-case basis whether one or more caregivers are 

needed.

•  Ensure that the sling selected meets the patient’s needs with reference to model, size, fabric and design.

•  

Test the emergency lowering device on the lift you are using to make certain that it functions properly. 

• 

Adjust the maximum height so that it will be impossible to raise a patient too high.

• For safety and hygiene reasons, use individual slings.
•  Before lifting, plan the lifting operation so that it can be done as safely and smoothly as possible.
• Before lifting, check that the lifting accessory hangs vertically and can move freely.
•   Although the Liko sling bars are equipped with latches, special caution must be exercised: before the patient is lifted from 

the underlying surface, but when the straps are fully extended, make sure the straps are correctly connected to the sling 

bar hooks.

•  Never lift a patient higher off the underlying surface than is needed to complete the lifting and transfer procedure.
•  Never leave a patient unattended during a lifting situation.
•  Make sure that the wheels on the wheelchair, bed, gurney, etc., are locked during the lifting/transfer operation.
• Always work ergonomically. Use the patient’s ability to actively participate in the operations.
• When the sling is not being used, do not place in direct sun light.

Safety Instructions

Liko’s products undergo continuous development, which is why we reserve the right to make product changes without prior 

notice. Contact your Hill-Rom representative for advice and information about product upgrades.

  Medical Device Class 

I

 Product

Liko MasterVest complies with the harmonized standard ISO10535:2006.

  IMPORTANT!

Lifting and transferring a patient always involves a certain risk. Read the instruction guide for both the lift and lifting 

accessories before use. It is important to completely understand the contents of the instruction guide. The equipment should 

be used only by trained personnel. Ensure that the lifting accessories are suitable for the lift being used. Exercise care and 

caution during use. As a caregiver, you are always responsible for the patient’s safety. You must be aware of the patient’s 

ability to handle the lifting situation.

The management system for both manufacturing and development of the product is certified in accordance with ISO9001 

and its equivalent for the medical device industry, ISO13485. The management system is also certified in accordance with the 

environmental standard ISO14001.

PATENT www.hill-rom.com/patents

May be covered by one or more patents. See above Internet address.

The Hill-Rom companies are the proprietors of European, US, and other patents and pending patent applications. 

Design and Quality by Liko in Sweden

Summary of Contents for MasterVest 3560 - 13

Page 1: ...bear patterned polyester fabric and this is why these slings are called TeddyVest Front closure MasterVest Mod 64 The front closure model of Liko MasterVest Mod 64 can be used for patients who are ab...

Page 2: ...ically Use the patient s ability to actively participate in the operations When the sling is not being used do not place in direct sun light Safety Instructions Liko s products undergo continuous deve...

Page 3: ...is used for bath or shower After use in bath and shower situations the sling should be placed so that it dries as soon as possible Washing Instructions Please see the sling s product label and the at...

Page 4: ...sterVest 7EN160168 Rev 8 www hill rom com I www liko com Sling bar Sling loops to sling bar hooks Correct SlingGuard Universal SlingGuard Twin Universal Twin Wrong How to Attach a Sling to Different S...

Page 5: ...5 Liko MasterVest 7EN160168 Rev 8 www hill rom com I www liko com How to Attach a MasterVest to a Twin Bar 1 2 3 B A B A A B Shoulder strap Loop strap B B A A...

Page 6: ...nds upright and in balance Lower the sling bar slightly to relieve pressure around the chest Now the patient has an opportunity to put weight on the legs and work on balance training Lifting from a Se...

Page 7: ...tween 5 cm 2 inch and 30 cm 12 inch The larger the size of the vest the wider the gap can be The size is to small when the gap between the metal D rings is too wide the loop straps do not reach up to...

Page 8: ...Adjust the loop strap by using an inner loop Choose a smaller size Try using a Liko MasterVest of plastic coated net Try using the leg harness Hold the vest in place behind the back while raising the...

Page 9: ...n two lengths Long 28 cm 11 inch Prod No 3156511 and Short 22 cm 9 inch Prod No 3156512 Short springs are recommended in cases where the lifting height does not permit the use of long springs For pati...

Page 10: ...and also SlingGuard 450 Prod No 3308020 and 3308520 Twin bars 670 relates to Universal TwinBar 670 Prod No 3156077 and 3156087 and also SlingGuard 670 Twin Prod No 3308040 and 3308540 Sling bar 350 re...

Reviews:

Related manuals for MasterVest 3560 - 13