LD220
6.11 Serial menu
The
Serial
menu allows to configure the basic settings of the serial interface
(terminal blocks 16, 17 and 18). For complete information on the serial port
features, please refer to the “4.7 Serial interface (-AVI- and -DO- order codes)”
section on page 26.
This function is only available for devices with order codes AVI and DO.
Unit number
This parameter allows to set the address of the serial device. You can assign to
the unit any address number between 11 and 99. The address must not contain
any “0“ because such numbers (20, 30, …) are reserved for collective addressing
(broadcast address).
11
Smallest address value
…
99
Highest address value
Serial baud rate
This parameter allows to set the serial transmission speed (baud rate).
Available options are:
0 9600
9600 baud
1 19200
19200 baud
2 38400
38400 baud
Serial format
This parameter allows to set the bit data format.
Data Bits
Parity Bit
Stop Bits
0
7-EVEN-1
7
even
1
1
7-EVEN-2
7
even
2
2
7-ODD-1
7
odd
1
3
7-ODD-2
7
odd
2
4
7-NONE-1
7
no
1
5
7-NONE-2
7
no
2
6
8-EVEN-1
8
even
1
7
8-ODD-1
8
odd
1
8
8-NONE-1
8
no
1
9
8-NONE-2
8
no
2
MAN LD220 E 1.4.odt
6 – Menus and parameters
71 of 100