SFA-5000 • SFA-10000 CANopen®
5 - Quick reference
Using the default settings provided by the manufacturer, you can switch on the
device and read immediately its position.
Follow the instructions below to:
read the physical resolution of the device: physical singleturn resolution
(
6501-00 Physical singleturn resolution
) and number of physical
revolutions (
6502-00 Number of hardware distinguishable
);
0;
set the
Operational
mode;
read the current position (in a cyclic mode and/or a synchronous mode).
Default Baud rate and Node ID are:
Baud rate = 500 Kbit/s
Node-ID = 1
Reading the physical resolution per revolution:
Master
Encoder
COB-ID
Cmd
Index
Sub
Process data
601
40
01
65
00
-
-
-
-
Encoder
Master
COB-ID
Cmd
Index
Sub
Process data
581
43
01
65
01
A0
A1
A2
A3
steps/rev. = ( (A3<<24) | (A2<<16) | (A1<<8) | A0 )
Reading the number of physical revolutions:
hardware distinguishable revolutions
Master
Encoder
COB-ID
Cmd
Index
Sub
Process data
601
40
02
65
00
-
-
-
-
Encoder
Master
COB-ID
Cmd
Index
Sub
Process data
581
43
02
65
01
B0
B1
B2
B3
N. rev. =( (B3<<24) | (B2<<16) | (B1<<8) | B0 )
MAN SFA_5000_10000_CB E 1.0.odt
5 - Quick reference
35 of 88