AMM8A SSI & BiSS C-mode
direction. We suggest setting the zero setting/preset function when the encoder
shaft is not running. If not used, connect the Zero setting/Preset input to 0Vdc.
WARNING
In the BiSS C-mode interface, the Zero setting/Preset input is active only when
the
(the bit 2 in the register 49 = 0, see on page 63); otherwise the hardware
function is disabled.
NOTE
In the BiSS C-mode interface, the preset can be activated also by using the
information please refer to the
register on page 62, the
5.5 +5Vdc OUT
The encoder provides an auxiliary voltage output to separately supply the circuit
or drive further electronics. It is over-current protected.
Output voltage: +5Vdc ±5%
Output current (max. load): max. 100 mA
It is not connected currently.
5.6 Input 1
This input is reserved for use by manufacturer.
5.7 Sine cosine signals
A (COSINE) and B (SINE) signals are to be intended with CW rotation as viewed
from the flange side (see the Figure on page 32). They provide 1024 sinusoidal
waves per each mechanical revolution with amplitude 1Vpp. 1Vpp output level
MAN AMM8A SSI_BiSS E 1.10.odt
5 - Electrical connections
34 of 80