background image

FITTING AND WIRING INSTRUCTIONS:

Important Things to Consider Before you Begin

1). Before commencing work, ALWAYS isolate the 

mains power supply and remove the fuse in the fuse 

box or switch off the circuit breaker in the consumer 

unit.

2). If unit is to be used as a replacement for an existing 

product, remove existing unit from its location and 

disconnect the wiring. Ensure that the wall (back) box 

has a minimum depth of 25mm.

3). Certain items in the range will not fit into a 4-lug 

box. If such a box has been previously installed the 

North-South lugs should be removed or bent back to 

avoid contact with the new product.

4). Connect the wires as shown in appropriate wiring 

diagrams. Use green/yellow sleeving on any earth 

conductors not insulated. Ensure terminals are 

properly tightened and no bare wire is visible. When 

mounting products into mounting boxes make sure 

conductors are not trapped.

5). When screwing the unit to the mounting box, do 

not over tighten fixing screws. Fixing screws are 

supplied with this product.

6). To reduce the risk of discolouration or tarnishing, 

avoid installation on wet plaster.

7). Products must be installed in accordance with the 

latest building and IEE wiring regulations. If in any 

doubt, please contact a qualified electrician.

Summary of Contents for connect JSJS LW240

Page 1: ...FERENCE AND FOR GUIDANCE ON THE ASSOCIATION OF REMOTE HANDSETS FOR HELP AND SETUP GUIDANCE PLEASE VISIT www lightwaverf com OVERVIEW connect LightwaveRF Amber LED OFF Blue LED ON It is important to in...

Page 2: ...the North South lugs should be removed or bent back to avoid contact with the new product 4 Connect the wires as shown in appropriate wiring diagrams Use green yellow sleeving on any earth conductors...

Page 3: ...equired for reliable LED operation For guidance on compatible bulbs please visit www lightwaverf com The 4 gang LightwaveRF Connect Dimmer is NOT compatible with Wirewound transformers generally older...

Page 4: ......

Page 5: ...itional slave units maximum of 6 in line will allow for 2 way multi way operation units can only be operated manually Max 8mm Min 13mm 6 Screw the dimmer switch to the mounting box and ensure that the...

Page 6: ...7 Replace the plate a click sound should be heard to signify that the plate has been correctly replaced...

Page 7: ...4 Gangs with 1 Way 4 Gangs with 2 Way...

Page 8: ...ode 2 Using a LightwaveRF Connect Remote press the ON button intended to be paired the blue light on the dimmer switch will flash to confirm that the remote is now paired NOTE Learning Mode lasts for...

Page 9: ...light on the dimmer switch will flash to confirm that the remote is now unpaired Clearing Memory will remove all paired remotes 1 On the relevant dimmer switch press and hold down both the ON and OFF...

Page 10: ...n the OFF button 3 After 1 sec the light will start to dim down 4 At the desired brightness level release the OFF button NOTE If the OFF button is not released the light will continue to dim until no...

Page 11: ...e OFF button on the remote 3 After 1 sec the light will start to dim down 4 At the desired brightness level release the OFF button NOTE If the OFF button is not released the light will continue to dim...

Page 12: ...er and receiver is too great to achieve reliable operation the LightwaveRF SIGNAL BOOSTER may be used in conjunction with this product to increase the signal strength over greater distances SPECIFICAT...

Reviews: