background image

Connect Series

Dimmer Switch (4 Gang)

Model No. JSJSLW440

Instruction Manual

www.lightwaverf.house

Version 2

Summary of Contents for MEGAMAN JSJSLW440

Page 1: ...Connect Series Dimmer Switch 4 Gang Model No JSJSLW440 Instruction Manual www lightwaverf house Version 2...

Page 2: ...e 1999 5 EC R TTE Directive 93 68 EEC CE Marking Directive Standards Applied in order to verify compliance Safety BS EN 60730 1 2011 Health R TTE EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 0...

Page 3: ...erstand how to safely turn off the electricity supply You will also need suitable electrical screwdrivers Please refer to the following installation and setup instructions This will guide you step by...

Page 4: ...lluminated the dimmer is on Overview Installation IMPORTANT All LightwaveRF products can be legally DIY installed in your own home however if in doubt always consult a qualified electrician or heating...

Page 5: ...live out Screw mounting hole Live in 2 Way switching connection Installation IMPORTANT If conducting an insulation resistance test all LightwaveRF products must be disconnected from the mains or dama...

Page 6: ...if applicable It may be useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new dimmer Some exis...

Page 7: ...equire a mains neutral wire to be connected they only require live in and switched live out 7 Screw the dimmer switch to the mounting box and ensure that the screws are sufficiently tight to support t...

Page 8: ...terminal in back box can be capped off instead if no terminal present Live wire In This should be brown or red in colour Switched live wire out This should be blue or black in colour The switched live...

Page 9: ...t 30cm apart in order to prevent the risk of any radio conflict that could disrupt remote operation Suitable lamps must be used with the dimmer or it will not function correctly See next section for c...

Page 10: ...y and should not be connected to 230V mains Important Never install and run power to a LightwaveRF 2 way dimmer switch before first installing and connecting the counterpart standard LightwaveRF dimme...

Page 11: ...nal cable input marked S must ONLY be connected to the wire running to the other dimmer NOT live mains this will cause irreparable damage 3 Core Cable From Lighting Circuit Live Live Earth Switched Li...

Page 12: ...amps see www lightwaverf house for further guidance and information Standard mains voltage incandescent low energy incandescent lighting min 20W max 250W GU10 and equivalent HI spot mains halogen lamp...

Page 13: ...ker slightly at high or low brightness levels especially if there is only a modest overall circuit load under 10W Stability can be achieved by a very slight adjustment to the dimming range of the Ligh...

Page 14: ...oing until flicker is observed At this point return to the previous stable increment optimum level by pressing the on button Dimming Range Setup allows the dimmer s range to be adjusted to one of five...

Page 15: ...ction in light output when using incandescent lamps bulbs In the vast majority of cases this should not be noticeable as the drop is very small ONLY dimmable lamps can be used even if the dimmers are...

Page 16: ...button once to switch the dimmer off amber LED indicator will illuminate Press and hold to lower the light level Manual operation Manual dimming NOTE When the on button is tapped to turn on the dimme...

Page 17: ...Lightwave Link this will always count as ONE controller and take up one memory slot even if you are using multiple smartphones tablets 1 On the dimmer switch press and hold down both the on and off b...

Page 18: ...xisting remotes is first unpaired see below 1 On the dimmer switch press and hold down both the off and on buttons until the blue and amber LEDs flash alternately then release them The dimmer switch i...

Page 19: ...liable operation the LightwaveRF Signal Booster may be used in conjunction with this product to increase the range Clearing the memory will remove all linked controllers 1 Press and hold down both the...

Page 20: ...er once to switch the dimmer on blue LED indicator will illuminate Use the slider to raise or lower the light level or press and hold the on or off button on any other LightwaveRF controller Press the...

Page 21: ...mmer is signified by a slow flashing amber LED To lock unlock the dimmer press the unlock button on the Smartphone App or Socket Locker If the Socket locker is misplaced the dimmers can be reset by tu...

Page 22: ...he dimmer automatically and turns the light on So when one of the kids needs to use the bathroom in the middle of the night the path is safely lit for them The light is then set to turn off once no mo...

Page 23: ...a group The Mood Controller allows you to set and recall your own favourite lighting scenes at the touch of a button You can dim all the lights for watching a movie or create a relaxed mood for entert...

Page 24: ...lamps plugged into Lightwave Power Sockets or Plug in Sockets Via the Lightwave Link every light can be controlled using a smartphone wherever you are So when you re away on holiday you can turn on li...

Page 25: ...re attached to the correct terminals a common mistake is to reverse these connections If these measures fail contact technical support via www lightwaverf house Problem The switch is powered amber or...

Page 26: ...dies of water in the path of the transmission If the problem persists try moving the controller Link closer to the dimmer or consider using a LightwaveRF Signal Booster to extend the range by relaying...

Page 27: ...over 35mm deep Q Is it legal for me to to install the dimmer A Yes it is fully legal to install LightwaveRF in your own home Q Is there a maximum number of bulbs I can control with the dimmer A You c...

Page 28: ...have their switch modules separated and interchanged disconnecting and removing dimmer modules will invalidate the warranty Q Can I expect a drop in light output with a LightwaveRF dimmer A Lightwave...

Page 29: ...20 240V 50Hz Output rating 3W 210W max per gang Incandescent Load 20W min 210W max per gang Back Box Depth 35mm min Earthing Requirement Not essential double insulated Standby Energy Use Less than 1W...

Page 30: ...www lightwaverf house Version 2 2 Quadrant Park Mundells Welwyn Garden City Herts AL7 1FS 01707 386035...