Lightwave LTW-4 Series Operation & Installation Instructions Download Page 1

Operation & Installation Instructions

LIGHTWAVE - Standard Systems

System

Rated Flow

System

Rated Flow

LTW-402

LTW-502

LTW-602

2 gpm

LTW-H405

LTW-H505

LTW-H605

5 gpm

LTW-403

LTW-503

LTW-603

3 gpm

LTW-H410

LTW-H510

LTW-H610

10 gpm

LTW-406

LTW-506

LTW-606

6 gpm

LTW-H415

LTW-H515

LTW-H615

15 gpm

LTW-410

LTW-510

LTW-610

11 gpm

LTW-H425

LTW-H525

LTW-H625

25 gpm

LTW-415

LTW-515

LTW-615

15 gpm

LTW-H440

LTW-H540

LTW-H640

40 gpm

LTW-420

LTW-520

LTW-620

21 gpm

LTW-4  

Series

LTW-H4  

Series

LTW-5 Series

LTW-6 Series

LTW-H5 Series

LTW-H6 Series

Summary of Contents for LTW-4 Series

Page 1: ...403 LTW 503 LTW 603 3 gpm LTW H410 LTW H510 LTW H610 10 gpm LTW 406 LTW 506 LTW 606 6 gpm LTW H415 LTW H515 LTW H615 15 gpm LTW 410 LTW 510 LTW 610 11 gpm LTW H425 LTW H525 LTW H625 25 gpm LTW 415 LTW...

Page 2: ...pply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home with no chance of microbiological contamination This is chemical free p...

Page 3: ...5 LTW 6 Controllers 14 LTW 5 LTW 6Power up Sequence 14 LTW 5 Operational Screens 15 LTW 6 Operational Screens 15 Lamp Countdown Sequence 16 System Service Suggested 17 Lamp Replacement LTW 4 systems 1...

Page 4: ...vice instructions if required 7 Do not use this system for any purpose other than what it was intended for Misuse of this system could potentially cause harm to the user or others 8 Your system is int...

Page 5: ...ment required will depend on parameters being treated Hardness 7 gpg 120 mg L if hardness level is 7 gpg or slightly below the quartz sleeve must be cleaned periodically in order to ensure effi cient...

Page 6: ...LTW 390007 Brass Nut UV SENSOR LTW RSB25 LTW 5 6 02 03 06 10 15 series LTW RSB35 LTW 520 LTW 620 series GLAND NUT LTW 320006 O RING LTW 300038 UV LAMP LTW RL210 02 series LTW RL290 03 series LTW RL470...

Page 7: ...60005 Euro LTW 260006 New Zealand Australian LTW 260008 British GLAND NUT LTW 320006 O RING LTW 300038 UV LAMP LTW RL210HO 05 series LTW RL330HO 10 series LTW RL420HO 15 series LTW RL600HO 25 series L...

Page 8: ...p near est the pressure system and measure the amount of water drawn off until the pump starts again Depending on the size of the container used it is acceptable to turn the faucet on and off to empty...

Page 9: ...ded as it will allow you to isolate the UV reactor This will allow for easier access in case maintenance is required See Figure 3 Step 3 Use the supplied fasteners to mount the UV reac tor to wood or...

Page 10: ...ASE NOTE DO NOT install a UV lamp inside the quartz sleeve without the sleeve spring in place Step 8 Install the UV sensor ordered separately Align the flat portion so it faces the gland nut end and m...

Page 11: ...ing you The key will plug into the lamp key port on the right side of the controller Figure 8 Step 13 Plug the lamp connector into the lamp Note the keying for proper alignment see Fig ure 7a 7b Inser...

Page 12: ...equire periodic cleaning At a minimum the quartz sleeve should be cleaned on an annual basis The following steps outline a basic cleaning procedure Step 1 If a by pass assembly is installed shut the i...

Page 13: ...r and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropyl alcohol using a clean lint free cloth Step 7 R...

Page 14: ...d description of the system s performance in addition to providing any applicable fault messages and system diagnostics The controllers used in both the LTW 5 and LTW 6 are identical The difference is...

Page 15: ...s by pressing the button located on the front of the controller LTW 6 Operational Screens On systems with the UV monitor the system will display the same screens as on the LTW 5 except the UV Intensit...

Page 16: ...dible chirp Past the zero day threshold the LED or display screen changes to solid red with a continuous buzzer LTW 5 LTW 6 LTW 4 At any point during this sequence the audible chirp or alarm can be de...

Page 17: ...the lamp is expired it must be replaced with the same part number as indicated on the Maintenance Parts screen or on the label on the reactor With the system powered down remove and discard the lamp k...

Page 18: ...l on the reactor or on the Maintenance parts screen Low UV Intensity Remove and clean the quartz sleeve and sensor Check water quality meets requirements on page 5 and add filtration as required Repla...

Page 19: ...any module that is not detected when plugged directly into the controller Refer to flow meter manual for detailed troubleshooting Warning After any hard alarm the home or facility should be disinfecte...

Page 20: ...ates from 90 265V 47 63Hz Order PN LTW 130014 only fits LTW H4 LTW H5 LTW H6 systems Temperature Relief Valve TRV On reaching a higher temperature the TRV is designed to drain a small amount of water...

Page 21: ...an be placed into a manual override mode allowing for the flow of water in an alarm condition Order PN LTW SOL1 4 20 mA MODULE Outputs a 4 20mA signal of the UV output to a remote device such as a dat...

Page 22: ...r Watts 8 15 22 39 50 42 Power Watts 14 20 30 49 62 51 Replacement Lamp LTW RL210 LTW RL290 LTW RL470 LTW RL820 LTW RL999 LTW RL850 Replacement Sleeve LTW QS210 LTW QS290 LTW QS470 LTW QS820 LTW QS999...

Page 23: ...0 5 m3 hr 0 6 m3 hr 1 1 m3 hr 1 8 m3 hr Port Size MNPT MNPT 1 MNPT 1 MNPT 1 MNPT Electrical 90 265V 50 60Hz 1 5A Max Plug Type American NEMA 5 15P Lamp Power Watts 18 34 45 67 101 Power Watts 20 36 48...

Page 24: ...s outlined below LIGHTWAVE s liability under this warranty shall be limited to repairing or replacing the product without charge F O B LIGHTWAVE s closest Distribution Facility or authorized service d...

Page 25: ...DISINFECTION PRODUCT AND IS GIVEN IN LIEU OF ANY OTHER WARRANTY TO THE EXTENT ALLOWED BY APPLICABLE LAW ANY AND ALL EXPRESS OR IMPLIED WARRANTIES NOT SET FORTH HEREIN ARE WAIVED AND DISCLAIMED INCLUD...

Page 26: ...2 6 P a g e...

Page 27: ...2 7 P a g e...

Page 28: ...Van Isle Water 461 Dupplin Rd Victoria BC V8Z 1B8 250 383 7145 vanislewater com PN 910415 Version Date 12 2020...

Reviews: