
13. Assembly Guides
UBEX series – Matrix Application Mode – User's Manual
182
13. Assembly Guides
UBEX series – Matrix Application Mode – User's Manual
182
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
13.3. SFP+ Module Changing in R-series Endpoints
The R-series endpoint devices are built with pre-installed SFP+ modules inside the enclosure. The modules
can be changed by the user in few simple steps.
SFP+ Modules inside the Enclosure
Type of the SFP+ module
Number of
modules
Optical Mode
Wavelength
2xMM-2xDUO
Finisar FTLX8574D3BCL
2
Multimode
850 nm
2xMM-QUAD
Finisar FTLX8574D3BCL
2
Multimode
850 nm
2xSM-2xDUO
Finisar FTLX1475D3BCL
2
Singlemode
1310 nm
2xSM-QUAD
Finisar FTLX1475D3BCL
2
Singlemode
1310 nm
2xSM-BiDi-DUO
Module A: Finisar FTLX2072D327
1
Singlemode
1271 nm
Module B: Finisar FTLX2072D333
1
1331 nm
Removal of the Original SFP+ Modules
Step 1. Disconnect
the device from the
power source
.
WARNING!
Never disassemble the device when it is connected to the power source. The unit is built with
open frame power supply module, touching of it when the device is under power is dangerous.
Step 2.
Remove five screws with a
PZ1 screwdriver
from the left side of the device (highlighted below with
green).
R-series endpoint device - left view
Step 3.
Remove five screws from the right side of the device (highlighted below with green).
R-series endpoint device - right view
Step 4.
Remove all five screws from the top cover of the device (highlighted below with green).
R-series endpoint device - top view
Step 5.
Remove the top cover cautiously.
ATTENTION!
The protective ground cable is connected to the top cover. Be sure that the connection is not
harmed when removing the cover.
Step 6.
Disconnect the LC patch cable connectors from the SFP+ modules.
Step 7.
Pull down on the handle bar of the modules.
Step 8.
Gently slide out the SFP+ modules from the slot.
Installation of the New SFP+ Modules
ATTENTION!
Always be sure the optical mode of the new modules. 2xMM-2xDUO / 2xMM-QUAD models
support
multimode
, 2xSM-2xDUO / 2xSM-QUAD / 2xSM-BiDi-DUO support
singlemode
SFP+ modules only.
Step 1.
Put up on the handle bar of the new modules.
Step 2.
Connect the modules to the SFP+ port slots.
Step 3.
Connect the LC patch cable connectors to the SFP+ modules.
Step 4.
Place back the top cover cautiously.
Step 5.
Screw back all 15 screws to the top, left, and right side of the cover plate of the device.