9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
107
9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
107
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
9.4.4. Query the Date and Time of the System
The query returns with the current date and time which is set in the MMU. The format is based on the
ISO 8601 standard.
Command and Response
#time #date
ç
GET•/MANAGEMENT/DATETIME.CurrentTime
æ
pr•/MANAGEMENT/DATETIME.CurrentTime=
<date_time>
Parameters
Parameter
Description
Formula
<date_time>
Current date and time
YYYY
-
MM
-
DD
T
HH
:
MM
:
SS
Example
ç
GET /MANAGEMENT/DATETIME.CurrentTime
æ
pr /MANAGEMENT/DATETIME.CurrentTime=2019-11-30T06:23:37
9.4.5. Setting of the Date and Time Manually
The date and time format is based on the ISO 8601 standard.
Command and Response
ç
CALL•/MANAGEMENT/DATETIME:setTime=
<date_time>
æ
mO•/MANAGEMENT/DATETIME:setTime=
Parameters
See at previous section.
Example
ç
CALL /MANAGEMENT/DATETIME:setTime=2019-12-24T20:00:15
æ
mO /MANAGEMENT/DATETIME.setTime=
9.4.6. Setting the NTP Server
DEFINITION:
The Network Time Protocol (NTP) is a networking protocol for clock synchronization
between computer systems over packet-switched, variable-latency data networks.
Command and Response
#ntp
ç
SET•/MANAGEMENT/DATETIME.NtpServerAddress=
<server_address>
æ
pw•/MANAGEMENT/DATETIME.NtpServerAddress=
<server_address>
Example
ç
SET /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org
æ
pw /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org
9.4.7. Enable/Disable NTP
DEFINITION:
The Network Time Protocol (NTP) is a networking protocol for clock synchronization
between computer systems over packet-switched, variable-latency data networks.
Command and Response
ç
SET•/MANAGEMENT/DATETIME.EnableNtp=
<logical_value>
æ
pw•/MANAGEMENT/DATETIME.EnableNtp=
<logical_value>
Parameters
Identifier
Parameter description
Value
Explanation
<logical_value>
NTP service is enabled or
disabled.
true
The NTP is enabled.
false
The NTP is disabled.
Example
ç
SET /MANAGEMENT/DATETIME.EnableNtp=true
æ
pw /MANAGEMENT/DATETIME.EnableNtp=true
9.4.8. Setting the Brightness of the LCD Screen
Command and Response
ç
SET•/SYS/CECU/LCD.Brightness=
<parameter>
æ
pw•/SYS/CECU/LCD.Brightness=
<parameter>
Parameters
The
<parameter>
of display brightness can be set between 0 and 10 values.
Example
ç
SET /SYS/CECU/LCD.Brightness=5
æ
pw /SYS/CECU/LCD.Brightness=5
9.4.9. Software Resetting the Device
The core application of the Matrix Management Unit can be restarted.
INFO:
The video signal transmission is
not
affected by the software resetting of the MMU.
Command and Response
#softreset
ç
CALL•/SYS:softReset()
æ
mO•/SYS:softReset=
Example
ç
CALL /SYS:softReset()
æ
mO /SYS:softReset=