6. Lightware Device Controller (LDC)
series – Extender Application Mode – User's Manual
87
6. Lightware Device Controller (LDC)
series – Extender Application Mode – User's Manual
87
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
6.10. Control Menu
The Ethernet control ports, the RS-232 port, and the Infrared input/output ports can be configured in the
Control menu.
6.10.1. Ethernet Tab
Clicking on the Ethernet port icon results opening the Port properties. The most important information and
settings are available on the panel.
#ethernet
Ethernet tab in the Control menu
Available settings and tools:
▪
Port naming;
▪
Enable/disable the port
;
▪
Mode
(Auto negotiation / 10Mbps half-duplex / 10Mbps full-duplex / 100Mbps half-duplex /
100Mbps full-duplex / 1000Mbps full-duplex).
▪
Reloading factory default settings
for the selected port.
6.10.2. RS-232 Tab
DIFFERENCE:
Only the UBEX-PRO20-HDMI-F110 model is built with RS-232 port.
Clicking on the RS-232 port icon results opening the Port properties. The most important information and
settings are available on the panel.
#rs232 #rs-232 #serial
RS-232 tab in the Control menu
Available settings and tools:
▪
Port naming;
▪
Baud rate
(4800 / 7200 / 9600 / 14400 / 19200 / 38400 / 57600 / 115200);
▪
Parity
(None / Odd / Even);
▪
Stop bits
(1 / 1.5 / 2);
▪
Command Injection enable
(enable / disable);
▪
TCP port number
;
▪
Send message
field - see more details about it in the
Sending Message via RS-232 Interface
(next page);
▪
Reloading factory default settings
for the selected port.