11. Assembly Guides
series – Extender Application Mode – User's Manual
157
11. Assembly Guides
series – Extender Application Mode – User's Manual
157
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
11.3. Air Filter Foam Changing in R-series Endpoints
The R-series endpoint devices are built with an exchangeable air filter foam in front of the fans which can be
easily removed for cleaning or changing.
Removal of the Air Filter
Step 1. Disconnect
the device from the
power source
.
WARNING!
Never remove the air filter when it is connected to the power source. The cooling fans behind
the foam are in operation when the device is on, touching the spinning parts may cause injury.
Step 2.
Remove the air filter foam
by fingers
or using a
forceps
or
clamp
.
Parameters of the Foam
Size
(in mm): 86W x 40H x 8D
Material
: 25ppi polyurethane air filter foam
Installation of the Air Filter
Place the
cleaned
or
new air filter foam
in front of the cooling fans. Take care that all corners of the foam are
inside the air filter slot.
11.4. Hidden USB Connector for Debug Purpose
UBEX endpoints are built with a standard USB 2.0 mini B-type connector which is hidden under the jog dial
control knob.
ATTENTION!
The USB connector is for debug purpose. Please use it only in case of the Lightware Support
requests it.
Follow the steps to reach the hidden USB connector:
Step 1.
Remove the rubber ring from the jog dial knob.
Step 2.
Find the screw in the side of the jog dial knob and use a
hexagon (Allen) key wrench size 1.3 mm
to loosen it.
Step 3.
Pull down the jog dial knob from the holder.
Step 4.
The USB mini connector is available now.
The location of the hidden USB mini connector