5. Installation
series – Matrix Application Mode – User's Manual
41
5. Installation
series – Matrix Application Mode – User's Manual
41
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
5.5.2. F-series Endpoints - Receiver Operation Mode
Connections for the F110 model in receiver operation mode
Changing the Operation Mode
The operation mode of the UBEX endpoint device can be changed using the following methods.
Before
connecting the device to the network and the MMU:
▪
via
front panel LCD menu
;
After
connecting the device to the network and the MMU:
▪
via
Lightware Device Controller (LDC) software
▪
via
LW3 protocol command
section.
For all F-series models
OPT
DAC
Connect singlemode or multimode (depends on the installed SFP+ modules) fiber
optical cables or DAC cables between the receiver and the Layer 3 (L3) network
switch. The Matrix Mode is detected and applied automatically in the device once
the MMU claims the endpoint.
Local HDMI in
Connect the local source devices (e.g. PC, Blu-ray player) using the HDMI input 1
and 2 ports by HDMI cables.
#new
HDMI out
Connect the sink devices (e.g. monitor, projector) to the HDMI output 1 and 2
ports by HDMI cables.
Ethernet
Optionally connect the receiver to a LAN in order to control the device.
Power
Connect the power adaptor to the AC input on the receiver first, then to the AC
power socket.
For F110 model only
Audio in
Connect an audio source device (e.g. MP3 player) to the audio input connector.
Audio out
Connect an audio sink device (e.g. audio amplifier) to the audio output connector.
IR in
Connect an Infrared detector unit to the IR IN connector for receiving Infrared
input signal.
IR out
Connect an Infrared emitter unit to the IR OUT connector for controlling third-party
devices over Infrared signal.
RS-232
Optionally for RS-232 extension: connect the controlled unit (e.g. projector) to the
RS-232 port of the device with a serial cable.
WARNING!
User Ethernet is also transmitted over the SFP+ interface so be sure not to create network
loop.
INFO:
The HDMI input ports can be used as local input ports only when the device is configured as receiver.