SF000 LiDAR Sensor
Product guide
Command list
If a command is not readable or writable then it can only be received from the SF000/B and not sent to it.
ID
Name
Description
RW
Read
bytes
Write
bytes
Persists
0
Product name
R
16
-
-
1
Hardware
revision
R
4
-
-
2
Firmware
revision
R
4
-
-
3
Serial number
R
16
-
-
7
Human readable
text message
-
-
-
-
9
16 byte store for
user data
RW
16
16
Y
10
Next
usable
safety token
R
2
-
-
12
Store persistent
parameters
W
-
2
-
14
Restart the unit
W
-
2
-
27
Distance output
configuration
RW
4
4
N
30
Current
data
stream type
RW
4
4
N
44
Measurement
distance data in
cm
R
varies
-
-
45
Measurement
distance data in
mm
R
varies
-
-
50
Is laser firing?
RW
1
1
N
30 of 47