8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
91
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
8.15.13. Query the Health State of a PSU Drawer
The query returns with the actual health status information about the selected PSU drawer.
Command and Response
ç
GETALL·/HEALTH/
<PSU>
æ
pr·/HEALTH/
<PSU>
.Enabled=
<logical_value>
æ
pr·/HEALTH/
<PSU>
.FanSpeed0=
<fanspeed>
æ
pr·/HEALTH/
<PSU>
.Temperature0=
<temperature>
æ
pr·/HEALTH/
<PSU>
.Current0=
<current0>
æ
pr·/HEALTH/
<PSU>
.Current1=
<current1>
æ
pr·/HEALTH/
<PSU>
.DcOk0=
<logical_value>
æ
pr·/HEALTH/
<PSU>
.DcOk1=
<logical_value>
æ
pr·/HEALTH/
<PSU>
.PowerGood0=
<logical_value>
æ
pr·/HEALTH/
<PSU>
.PowerGood1=
<logical_value>
æ
pr·/HEALTH/
<PSU>
.TemperatureState=
<status>
æ
pr·/HEALTH/
<PSU>
.CurrentState=
<status>
æ
pr·/HEALTH/
<PSU>
.FanState=
<status>
æ
pr·/HEALTH/
<PSU>
.PowerDrawerState=
<status>
æ
pr·/HEALTH/
<board>
.OverallHealthState=
<status>
æ
pr·/HEALTH/
<board>
.Status=
<status>
æ
pr·/HEALTH/
<PSU>
.ProductName=
<product_name>
æ
pr·/HEALTH/
<PSU>
.SerialNumber=
<serial_number>
æ
pr·/HEALTH/
<PSU>
.PartNumber=
<part_number>
Parameters
Identifier
Parameter
description
Value
Value description
<PSU>
The identifier of
the PSU drawer.
POWERDRAWER1
PSU drawer 1
POWERDRAWER2
PSU drawer 2
Layout of the Matrix
Example
ç
GETALL /HEALTH/POWERDRAWER1
æ
pr /HEALTH/POWERDRAWER1.Enabled=true
æ
pr /HEALTH/POWERDRAWER1.FanSpeed0=0.00 RPM;10.00;65535.00;0.00;65535.00;0.00;0.00
æ
pr /HEALTH/POWERDRAWER1.Temperature0=0.00 C;0.00;100.00;0.00;110.00;0.00;0.00
æ
pr /HEALTH/POWERDRAWER1.Current0=59.11 A;0.00;38.00;0.00;42.00;59.11;59.11
æ
pr /HEALTH/POWERDRAWER1.Current1=0.00 A;0.00;14.00;0.00;15.60;0.00;0.00
æ
pr /HEALTH/POWERDRAWER1.DcOk0=true
æ
pr /HEALTH/POWERDRAWER1.DcOk1=true
æ
pr /HEALTH/POWERDRAWER1.PowerGood0=true
æ
pr /HEALTH/POWERDRAWER1.PowerGood1=true
æ
pr /HEALTH/POWERDRAWER1.TemperatureState=OK
æ
pr /HEALTH/POWERDRAWER1.CurrentState=OK
æ
pr /HEALTH/POWERDRAWER1.FanState=OK
æ
pr /HEALTH/POWERDRAWER1.PowerDrawerState=Operational
æ
pr /HEALTH/POWERDRAWER1.OverallHealthState=OK
æ
pr /HEALTH/POWERDRAWER1.Status=Operational
æ
pr /HEALTH/POWERDRAWER1.ProductName=MX2M-PSU-500-F
æ
pr /HEALTH/POWERDRAWER1.SerialNumber=87654321
æ
pr /HEALTH/POWERDRAWER1.PartNumber=