8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
89
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
8.15.8. Query the Fan Warnings
The query returns with a semi-colon separated list of the devices that have an active system fan warning.
Command and Response
ç
GET·/HEALTH.FanWarning
æ
pr·/HEALTH.FanWarning=
<fan1>
;
<fan2>
;...
<fanN>
Example
ç
GET /HEALTH.FanWarning
æ
pr /HEALTH.FanWarning=
8.15.9. Query the Fan Errors
The query returns with a semi-colon separated list of the devices that have an active system fan error.
Command and Response
ç
GET·/HEALTH.FanError
æ
pr·/HEALTH.FanError=
<fan1>
;
<fan2>
;...
<fanN>
Example
ç
GET /HEALTH.FanError
æ
pr /HEALTH.FanError=
8.15.10. Query the PSU Drawer Warnings
The query returns with a semi-colon separated list of the devices that have an active power supply unit (PSU)
warning.
Command and Response
ç
GET·/HEALTH.PsuWarning
æ
pr·/HEALTH.PsuWarning=
<PSU1>
;
<PSU2>
Example
ç
GET /HEALTH.PsuWarning
æ
pr /HEALTH.PsuWarning=
8.15.11. Query the PSU Drawer Errors
The query returns with a semi-colon separated list of the devices that have an active power supply unit (PSU)
error.
WARNING!
If a device has active PSU drawer error, power off the device as soon as possible.
Command and Response
ç
GET·/HEALTH.PsuError
æ
pr·/HEALTH.PsuError=
<PSU1>
;
<PSU2>
Example
ç
GET /HEALTH.PsuError
æ
pr /HEALTH.PsuError=